Impact of venous return on pulmonary oxygen uptake kinetics during dynamic exercise: in silico time series analyses from muscles to lungs

Author:

Drescher Uwe1

Affiliation:

1. Institute of Physiology and Anatomy, German Sport University Cologne, Cologne, Germany

Abstract

The aim of the present study was to investigate whether a single-compartment (SCM) and a multi-compartment (MCM) venous return model will produce significantly different time-delaying and distortive effects on pulmonary oxygen uptake (V̇o2pulm) responses with equal cardiac outputs (Q̇) and muscle oxygen uptake (V̇o2musc) inputs. For each model, 64 data sets were simulated with alternating Q̇ and V̇o2musc kinetics—time constants (τ) ranging from 10 to 80 s—as responses to pseudorandom binary sequence work rate (WR) changes. Kinetic analyses were performed by using cross-correlation functions (CCFs) between WR with V̇o2pulm and V̇o2musc. Higher maxima of the CCF courses indicate faster system responses—equal to smaller τ values of the variables of interest (e.g., τV̇o2musc). The models demonstrated a highly significant relationship for the resulting V̇o2pulm responses ( r = 0.976, P < 0.001, n = 64). Both models showed significant differences between V̇o2pulm and V̇o2musc kinetics for τV̇o2musc ranging from 10 to 30 s ( P < 0.05 each). In addition, a significant difference in V̇o2pulm kinetics ( P < 0.05) between the models was observed for very fast V̇o2musc kinetics (τ = 10 s). The combinations of fast Q̇ dynamics and slow V̇o2musc kinetics yield distinct deviations in the resultant V̇o2pulm responses compared with V̇o2musc kinetics. Therefore, the venous return models should be used with care and caution if the aim is to infer V̇o2musc by means of V̇o2pulm kinetics. Finally, the resultant V̇o2pulm responses seem to be complex and most likely unpredictable if no cardiodynamic measurements are available in vivo. NEW & NOTEWORTHY A single-compartment and a multi-compartment venous return model were tested to see whether they result in different pulmonary oxygen uptake (V̇o2pulm) kinetics from equal cardiac output and muscle oxygen uptake (V̇o2musc) kinetics. To infer V̇o2musc kinetics by means of V̇o2pulm kinetics, both models should only be used for V̇o2musc time constants ranging from 40 to 80 s. The resultant V̇o2pulm responses seem to be complex and most likely unpredictable if no cardiodynamic measurements are available.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3