The hydrostatic pressure indifference point underestimates orthostatic redistribution of blood in humans

Author:

Petersen L. G.1,Carlsen J. F.2,Nielsen M. B.2,Damgaard M.3,Secher N. H.4

Affiliation:

1. Department of Biomedical Sciences, The Panum Institute, University of Copenhagen, Copenhagen, Denmark;

2. Department of Radiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark;

3. Department of Clinical Physiology and Nuclear Medicine, Køge Sygehus, Køge, Denmark; and

4. Department of Anesthesia, The Copenhagen Muscle Research Center, Rigshopitalet, University of Copenhagen, Copenhagen, Denmark

Abstract

The hydrostatic indifference point (HIP; where venous pressure is unaffected by posture) is located at the level of the diaphragm and is believed to indicate the orthostatic redistribution of blood, but it remains unknown whether HIP coincides with the indifference point for blood volume (VIP). During graded (± 20°) head-up (HUT) and head-down tilt (HDT) in 12 male volunteers, we determined HIP from central venous pressure and VIP from redistribution of both blood, using ultrasound imaging of the inferior caval vein (VIPui), and fluid volume, by regional electrical admittance (VIPadm). Furthermore, we evaluated whether inflation of medical antishock trousers (to 70 mmHg) affected HIP and VIP. Leaving cardiovascular variables unaffected by tilt, HIP was located 7 ± 4 cm (mean ± SD) below the 4th intercostal space (IC-4) during HUT and was similar (7 ± 3 cm) during HDT and higher ( P < 0.0001) than both VIPui (HUT: 22 ± 16 cm; HDT: 13 ± 7 cm) and VIPadm (HUT: 29 ± 9 cm; HDT: 20 ± 9 cm below IC-4). During HUT antishock trousers elevated both HIP and VIPui [to 3 ± 5 cm ( P = 0.028) and 17 ± 7 cm below IC-4 ( P = 0.051), respectively], while VIPadm remained unaffected. By simultaneous recording of pressure and filling of the inferior caval vein as well as fluid distribution, we found HIP located corresponding to the diaphragm while VIP was placed low in the abdomen, and that medical antishock trousers elevated both HIP and VIP. The low indifference point for volume shows that the gravitational influence on distribution of blood is more profound than indicated by the indifference point for venous pressure.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3