Assessment of cardiac output with transpulmonary thermodilution during exercise in humans

Author:

Calbet José A. L.123,Boushel Robert34

Affiliation:

1. Department of Physical Education, University of Las Palmas de Gran Canaria, Campus Universitario de Tafira, Las Palmas de Gran Canaria, Spain;

2. Research Institute of Biomedical and Health Sciences, IUIBS, University of Las Palmas de Gran Canaria, Canary Island, Spain;

3. Copenhagen Muscle Research Center, Heart & Circulatory Section, Department of Biomedical Sciences, University of Copenhagen, and Department of Anaesthesia, Bispebjerg Hospital, Copenhagen, Denmark; and

4. Åstrand Laboratory, The Swedish School of Sport and Health Sciences, Stockholm, Sweden

Abstract

The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remains unknown if this technique is also accurate and reproducible during exercise. Sixteen healthy men underwent catheterization of the right femoral vein (for iced saline injection), an antecubital vein (ICG injection), and femoral artery (thermistor) to determine their Q̇ by TPTd and ICG concentration during incremental one- and two-legged pedaling on a cycle ergometer and combined arm cranking with leg pedaling to exhaustion. There was a close relationship between TPTd-Q̇ and ICG-Q̇ ( r = 0.95, n = 151, standard error of the estimate: 1.452 l/min, P < 0.001; mean difference of 0.06 l/min; limits of agreement −2.98 to 2.86 l/min), and TPTd-Q̇ and ICG-Q̇ increased linearly with oxygen uptake with similar intercepts and slopes. Both methods had mean coefficients of variation close to 5% for Q̇, global end-diastolic volume, and intrathoracic blood volume. The mean coefficient of variation of EVLW, assessed with both indicators (ICG and thermal) was 17% and was sensitive enough to detect a reduction in EVLW of 107 ml when changing from resting supine to upright exercise. In summary, TPTd with bolus injection into the femoral vein is an accurate and reproducible method to assess Q̇ during exercise in humans.

Funder

Ministerio de Educación y Ciencia

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3