Direct comparison of in vivo Achilles tendon moment arms obtained from ultrasound and MR scans

Author:

Fath Florian1,Blazevich Anthony J.2,Waugh Charlie M.1,Miller Stuart C.13,Korff Thomas1

Affiliation:

1. Centre for Sports Medicine and Human Performance, Brunel University,

2. School of Exercise, Biomedical, and Health Sciences, Edith Cowan University, Perth, Western Australia

3. London Sport Institute, Middlesex University, London, United Kingdom; and

Abstract

Accurate and reliable estimation of muscle moment arms is a prerequisite for the development of musculoskeletal models. Numerous techniques are available to estimate the Achilles tendon moment arm in vivo. The purposes of this study were 1) to compare in vivo Achilles tendon moment arms obtained using the center of rotation (COR) and tendon excursion (TE) methods and 2) to assess the reliability of each method. For the COR method, magnetic resonance (MR) images from nine participants were obtained at ankle angles of −15°, 0°, and +15° and analyzed using Reuleaux' method. For the TE method, the movement of the gastrocnemius medialis-Achilles tendon junction was recorded using ultrasonography as the ankle was passively rotated through its range of motion. The Achilles tendon moment arm was obtained by differentiation of tendon displacement with respect to ankle angular excursion using seven different differentiation techniques. Moment arms obtained using the COR method were significantly greater than those obtained using the TE method ( P < 0.01), but results from both methods were well correlated. The coefficient of determination between moment arms derived from the COR and TE methods was highest when tendon displacement was linearly differentiated over a ±10° interval ( R2 = 0.94). The between-measurement coefficient of variation was 3.9% for the COR method and 4.5–9.7% for the TE method, depending on the differentiation technique. The high reliabilities and strong relationship between methods demonstrate that both methods are robust against their limitations. The large absolute between-method differences (∼25–30%) in moment arms have significant implications for their use in musculoskeletal models.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3