Effect of net gas volume changes on alveolar and arterial gas partial pressures in the presence of ventilation-perfusion mismatch

Author:

Korman Ben1,Dash Ranjan K.2,Peyton Philip J.3

Affiliation:

1. Department of Anaesthesia and Pain Medicine, Royal Perth Hospital, Perth, Western Australia, Australia

2. Departments of Biomedical Engineering and Physiology, Medical College of Wisconsin, Milwaukee, Wisconsin

3. Anaesthesia, Perioperative, and Pain Medicine Unit, Melbourne Medical School, University of Melbourne, Department of Anaesthesia, Austin Health, Heidelberg, Victoria, Australia

Abstract

The second gas effect (SGE) occurs when nitrous oxide enhances the uptake of volatile anesthetics administered simultaneously. Recent work shows that the SGE is greater in blood than in the gas phase, that this is due to ventilation-perfusion mismatch, that as mismatch increases, the SGE increases in blood but is diminished in the gas phase, and that these effects persist well into the period of nitrous oxide maintenance anesthesia. These modifications of the SGE are most pronounced with the low soluble agents in current use. We investigate further the effect of net gas volume loss during nitrous oxide uptake on low concentrations of other gases present using partial pressure-solubility diagrams. The steady-state equations of gas exchange were solved assuming a log-normal distribution of ventilation-perfusion ratios using Lebesgue-Stieltjes integration. It was shown that under these conditions the classical partial pressure-solubility diagram must be modified, that for currently used volatile anesthetic agents the alveolar-arterial partial pressure difference is less than that predicted in the past, and that the alveolar-arterial partial pressure difference may even be reversed during uptake in the case of highly insoluble gases such as sulfur hexafluoride. Comparing this with the situation described previously for nitrogen in steady-state air breathing, we show that for nitrogen, the direction of the alveolar-arterial gradient is opposite to the direction of net gas volume movement. Although gas uptake with ventilation-perfusion inequality exceeding that when matching is optimal is shown to be possible, it is less likely than alveolar-arterial partial pressure reversal. NEW & NOTEWORTHY Net uptake of gases administered with nitrous oxide may proceed against an alveolar-arterial partial pressure gradient. The alveolar-arterial gradient for nitrogen in the steady-state breathing air depends not only on the existence of a distribution of ventilation-perfusion ratios in the lung but also on the presence of a net change in gas volume and is opposite in direction to the direction of net gas volume uptake.

Funder

National Institute of Health

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3