Estimation of lung liquid production in fetal sheep with blue dye dextran and radioiodinated serum albumin

Author:

Cassin S.1,Perks A. M.1

Affiliation:

1. Department of Physiology, University of Florida College of Medicine, Gainesville, Florida 32610; and Department of Obstetrics and Gynecology, University of British Columbia, Vancouver, British Columbia, Canada V6H 3V5

Abstract

Lung liquid production and reabsorption rates and lung volumes were measured in 99 fetal sheep (119–148 days of gestation) by indicator-dilution methods with the simultaneous use of blue dye dextran (BDD) and radioiodinated serum albumin (RISA). There were no significant differences between rates of lung liquid production or reabsorption by the two methods ( n = 71 pairs; paired t-test; Wilcoxon test; ANOVA); this was equally true for rates in milliliters per hour or milliliters per kilogram body weight per hour and was independent of age. Volumes measured by both methods showed a close linear relationship ( r = 0.97; for slope P < 0.0001; n = 99), whether expressed as milliliters or milliliters per kilogram body weight. Either method could give the higher volume. Values differed by only ∼4%, independent of age or parameter (ml or ml/kg body wt; volumes regressed to original volume, or as measured in untreated control hours). However, this small difference was significant by paired t-test or Wilcoxon test when all data were combined irrespective of age; it was not significant after allowance for gestational age (two-way ANOVA). Both indicators showed the same increase in lung volume toward birth and the same fall when related to body weight (slopes significant P = 0.0003–0.0004; r = 0.93). Two-way ANOVA showed that the declines were significant ( P = 0.003). The data suggest that 1) there was no significant difference in production or reabsorption rates measured by BDD or RISA, 2) differences in volumes measured by the two indicators were only significant if gestational age was ignored and were too small to have physiological importance, and 3) although BDD and RISA each may have methodological weaknesses, for purposes of measuring lung liquid volumes both are sufficiently accurate and reproducible to obtain meaningful physiological results.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3