Comparison of methods of chemical loop gain measurement during tidal ventilation in awake healthy subjects

Author:

Bokov Plamen123,Matrot Boris1,Gallego Jorge1,Delclaux Christophe123ORCID

Affiliation:

1. INSERM, UMR1141, Hôpital Universitaire Robert Debré, Paris, France

2. Service de Physiologie Pédiatrique, Hôpital Universitaire Robert Debré, AP-HP, Paris, France

3. Faculté de Médecine, Université Paris Diderot, Sorbonne Paris Cité, Paris, France

Abstract

The loop gain (LG) is defined as the ratio of a ventilatory response over the perturbation in ventilation, and it is used to analyze ventilatory control stability. The LG can be derived from minute ventilation (V̇e), end-tidal Pco2 ([Formula: see text]), and end-tidal Po2 ([Formula: see text]) values. Several methods of LG assessment have been developed, which have never been compared. We evaluated the computability, the short-term repeatability, and the agreement of six published (or slightly modified) models for LG determination. These models included three unconstrained autoregressive models, univariate (V̇e), bivariate (V̇e, [Formula: see text]), and trivariate (V̇e, [Formula: see text], and [Formula: see text]), and three analytical transfer function constrained models based on V̇e, V̇e and CO2-sensitivity, and V̇e and central and peripheral CO2 sensitivities, respectively. The models were tested with tidal breathing data in 37 awake healthy subjects (median age 35 yr; 23 women, 14 men). Modeling failed in 11, 0, and 0 subjects for the three unconstrained models, respectively, and 4, 1, and 9 subjects for the three constrained models, respectively. Bland and Altman analyses of the LG values in the medium frequency range of two separate recordings demonstrated good repeatability for four models, excluding univariate and trivariate unconstrained models. The four repeatable models gave LG values that were in agreement (medium frequency LG, median 0.100–0.210), although the constrained model based on V̇e systematically overestimated LG values. The variances explained by these models were ∼20%. In conclusion, model-based analyses of tidal breathing were performed with different approaches that gave comparable results for chemical LG and explained variance. NEW & NOTEWORTHY Several methods of chemical loop gain measurement have been published but never compared. We show that a better repeatability is obtained with analytical constrained models compared with autoregressive unconstrained models and that the repeatable models gave comparable results of loop gain, even if the calculation based on ventilation-only recording gave higher values than those obtained with both ventilation and end-tidal Pco2 recording. The explained variance of ventilation was similar whatever the model.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3