Effects of an artificial gravity countermeasure on orthostatic tolerance, blood volumes and aerobic power after short-term bed rest (BR-AG1)

Author:

Linnarsson Dag1,Hughson Richard L.2,Fraser Katelyn S.2,Clément Gilles3,Karlsson Lars L.1,Mulder Edwin4,Paloski William H.56,Rittweger Jörn47,Wuyts Floris L8,Zange Jochen4

Affiliation:

1. Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden;

2. Schlegel-University of Waterloo Research Institute for Aging, Faculty of Applied Health Sciences, University of Waterloo, Waterloo, Ontario, Canada;

3. International Space University, Illkirch-Graffenstaden, France;

4. Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany;

5. Neuroscience Research Laboratories, National Aeronautics and Space Administration/Johnson Space Center, Houston, Texas;

6. Center for Neuromotor and Biomechanics Research, University of Houston, Houston, Texas;

7. Institute for Biomedical Research into Human Movement and Health, Manchester Metropolitan University, Manchester, United Kingdom; and

8. Department of Otolaryngology, Antwerp University Research Center for Equilibrium and Aerospace, Antwerp, Belgium

Abstract

Exposure to artificial gravity (AG) in a short-arm centrifuge has potential benefits for maintaining human performance during long-term space missions. Eleven subjects were investigated during three campaigns of 5 days head-down bed rest: 1) bed rest without countermeasures (control), 2) bed rest and 30 min of AG (AG1) daily, and 3) bed rest and six periods of 5 min AG (AG2) daily. During centrifugation, the supine subjects were exposed to AG in the head-to-feet direction with 1 G at the center of mass. Subjects participated in the three campaigns in random order. The cardiovascular effects of bed rest and countermeasures were determined from changes in tolerance to a head-up tilt test with superimposed lower body negative pressure (HUT), from changes in plasma volume (PV) and from changes in maximum aerobic power (V̇o2peak) during upright work on a cycle ergometer. Complete data sets were obtained in eight subjects. After bed rest, HUT tolerance times were 36, 64, and 78% of pre-bed rest baseline during control, AG1 and AG2, respectively, with a significant difference between AG2 and control. PV and V̇o2peak decreased to 85 and 95% of pre-bed rest baseline, respectively, with no differences between the treatments. It was concluded that the AG2 countermeasure should be further investigated during future long-term bed rest studies, especially as it was better tolerated than AG1. The superior effect of AG2 on orthostatic tolerance could not be related to concomitant changes in PV or aerobic power.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3