Breathing patterns during cardiac arrest

Author:

Haouzi Philippe12,Ahmadpour Nasrollah1,Bell Harold J.1,Artman Stephen2,Banchs Javier2,Samii Soraya2,Gonzalez Mario2,Gleeson Kevin1

Affiliation:

1. Division of Pulmonary, Allergy, and Critical Care Medicine, Department of Medicine, College of Medicine, Pennsylvania State University, and

2. Heart and Vascular Institute, Penn State Milton Hershey Medical Center, Hershey, Pennsylvania

Abstract

The absence of respiratory movements is a major criterion recommended for use by bystanders for recognizing an out-of-hospital cardiac arrest (CA), as the persistence of eupneic breathing is considered to be incompatible with CA. The basis for CA-related apnea is, however, uncertain, since brain stem Po2 is not expected to drop immediately to the critical level where anoxic apnea occurs. It is therefore essential on both clinical and physiological grounds to determine whether and when breathing stops after the onset of CA. In eight patients, we measured the ventilatory response at the onset of ventricular fibrillation (VF) for 12–15 s during the placement of an implantable cardioverter-defibrillator device. We found that regular eupneic breathing was maintained unchanged despite the cessation of systemic and pulmonary blood flow generated by the heart. We extended these findings in adult sheep and found that, as in humans, the normal ventilatory pattern persists unchanged for the first 15 s despite the drop in blood pressure, followed by a progressive increase in minute ventilation, which was sustained for up to 164 s. The ensuing apnea was disrupted by typical gasps occurring at a very slow frequency. These observations suggest a complete “decoupling” between the return of CO2 to the pulmonary circulation and continued effective respiratory activity, contrary to what we predicted. This delayed cessation of eupneic breathing during the absence of cardiac pump function is likely related to the time needed for brain stem anoxia to develop. These findings challenge the notions that 1) ventilation stops as pulmonary blood flow/cardiac output ceases and 2) the presence of eupneic breathing is a reliable sign of effective cardiac pumping activity.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3