Abstract

Key elements for determining alveolar-capillary membrane conductance (Dm) and pulmonary capillary blood volume (Vc) from the lung diffusing capacity (Dl) for carbon monoxide (DlCO) or for nitric oxide (DlNO) are the reaction rate of carbon monoxide with hemoglobin (θCO) and the DmCO/DlNOrelationship (α-ratio). Although a range of values have been reported, currently there is no consensus regarding these parameters. The study purpose was to define optimal parameters (θCO, α-ratio) that would experimentally substantiate calculations of Dm and Vc from the single-inspired O2tension [inspired fraction of O2(FiO2)] method relative to the multiple-FiO2method. Eight healthy men were studied at rest and during moderate exercise (80-W cycle). Dm and Vc were determined by the multiple-FiO2and single-FiO2methods (rebreathe technique) and were tabulated by applying previously reported θCOequations (both methods) and by varying the α-ratio (single-FiO2method) from 1.90 to 2.50. Values were then compared between methods throughout the examined α-ratios. Dm and Vc were critically dependent on the applied θCOequation. For the multiple-FiO2method, Dm was highly variable between θCOequations (rest and exercise); the range of Vc was less widespread. For the single-FiO2method, the θCOequation by Reeves and Park (1992) combined with an α-ratio between 2.08 and 2.26 gave values for Dm and Vc that most closely matched those from the multiple-FiO2method and were also physiologically plausible compared with predicted values. We conclude that the parameters used to calculate Dm and Vc values from the single-FiO2method (using DlCOand DlNO) can significantly influence results and should be evaluated within individual laboratories to obtain optimal values.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3