GAPDH and β-actin protein decreases with aging, making Stain-Free technology a superior loading control in Western blotting of human skeletal muscle

Author:

Vigelsø Andreas1,Dybboe Rie1,Hansen Christina Neigaard1,Dela Flemming1,Helge Jørn W.1,Guadalupe Grau Amelia1

Affiliation:

1. Center for Healthy Aging, Department of Biomedical Sciences, Faculty of Health Sciences, University of Copenhagen, Denmark

Abstract

Reference proteins (RP) or the total protein (TP) loaded is used to correct for uneven loading and/or transfer in Western blotting. However, the signal sensitivity and the influence of physiological conditions may question the normalization methods. Therefore, three widely used reference proteins [β-actin, glyceraldehyde 3-phosphate dehydrogenase (GAPDH), and α-tubulin], as well as TP loaded measured by Stain-Free technology (SF) as normalization tool were tested. This was done using skeletal muscle samples from men subjected to physiological conditions often investigated in applied physiology where the intervention has been suggested to impede normalization (ageing, muscle atrophy, and different muscle fiber type composition). The linearity of signal and the methodological variation coefficient was obtained. Furthermore, the inter- and intraindividual variation in signals obtained from SF and RP was measured in relation to ageing, muscle atrophy, and different muscle fiber type composition, respectively. A stronger linearity of SF and β-actin compared with GAPDH and α-tubulin was observed. The methodological variation was relatively low in all four methods (4–11%). Protein level of β-actin and GAPDH was lower in older men compared with young men. In conclusion, β-actin, GAPDH, and α-tubulin may not be used for normalization in studies that include subjects with a large age difference. In contrast, the RPs may not be affected in studies that include muscle wasting and differences in muscle fiber type. The novel SF technology adds lower variation to the results compared with the existing methods for correcting for loading inaccuracy in Western blotting of human skeletal muscle in applied physiology.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3