A novel, fully implantable, multichannel biotelemetry system for measurement of blood flow, pressure, ECG, and temperature

Author:

Axelsson M.,Dang Q.,Pitsillides K.,Munns S.,Hicks J.,Kassab G. S.

Abstract

Biotelemetry provides high-quality data in awake, free-ranging animals without the effects of anesthesia and surgery. Although many biological parameters can be measured using biotelemetry, simultaneous telemetric measurements of pressure and flow have not been available. The objective of this study was to evaluate simultaneous measurements of blood flow, pressure, ECG, and temperature in a fully implantable system. This novel system allows the measurement of up to four channels of blood flow, up to three channels of pressure, and a single channel each of ECG and temperature. The system includes a bidirectional radio-frequency link that allows the implant to send data and accept commands to perform various tasks. The system is controlled by a base station decoder/controller that decodes the data stream sent by the implant into analog signals. The system also converts the data into a digital data stream that can be sent via ethernet to a remote computer for storage and/or analysis. The system was chronically implanted in swine and alligators for up to 5 wk. Both bench and in vivo animal tests were performed to evaluate system performance. Results show that this biotelemetry system is capable of long-term accurate monitoring of simultaneous blood flow and pressure. The system allows, within the room, recordings, since the implant transmission range is between 6 and 10 m, and, with a relay, backpack transmission distance of up to 500 m can be achieved. This system will have significant utility in chronic models of cardiovascular physiology and pathology.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Reference28 articles.

1. Integrated circuits for a bidirectional implantable pulsed Doppler ultrasonic blood flowmeter

2. Allen HV, Knutti JW, Meindl JD.Totally implantable directional Doppler flowmeter.Biotelem Patient Monit6: 118–132, 1979.

3. Axelsson M, Franklin C.From anatomy to angioscopy: 164 years of crocodilian cardiovascular research, recent advances and speculations.Comp Biochem Physiol118A: 51–62, 1997.

4. Gut blood flow in the estuarine crocodile,Crocodylus porosus

5. Flow dynamics of the crocodilian heart

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献