Effect of volume status on the estimation of mean systemic filling pressure

Author:

Werner-Moller Per12,Sondergaard Soren3ORCID,Jakob Stephan M.1,Takala Jukka1,Berger David1

Affiliation:

1. Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

2. Department of Anesthesiology and Intensive Care Medicine, Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital Ostra, Gothenburg, Sweden

3. Centre of Elective Surgery, Silkeborg Regional Hospital, Silkeborg, Denmark

Abstract

Various methods for indirect assessment of mean systemic filling pressure (MSFP) produce controversial results compared with MSFP at zero blood flow. We recently reported that the difference between MSFP at zero flow measured by right atrial balloon occlusion (MSFPRAO) and MSFP estimated using inspiratory holds depends on the volume status. We now compare three indirect estimates of MSFP with MSFPRAO in euvolemia, bleeding, and hypervolemia in a model of anesthetized pigs ( n = 9) with intact circulation. MSFP was estimated using instantaneous beat-to-beat venous return during tidal ventilation (MSFPinst_VR), right atrial pressure-flow data pairs at flow nadir during inspiratory holds (MSFPnadir_hold), and a dynamic model analog adapted to pigs (MSFPa). MSFPRAO was underestimated by MSFPnadir_hold and MSFPa in all volume states. Volume status modified the difference between MSFPRAO and all indirect methods (method × volume state interaction, P ≤ 0.020). All methods tracked changes in MSFPRAO concordantly, with the lowest bias seen for MSFPa [bias (confidence interval): −0.4 (−0.7 to −0.0) mmHg]. We conclude that indirect estimates of MSFP are unreliable in this experimental setup. NEW & NOTEWORTHY For indirect estimations of MSFP using inspiratory hold maneuvers, instantaneous beat-to-beat venous return, or a dynamic model analog, the accuracy was affected by the underlying volume state. All methods investigated tracked changes in MSFPRAO concordantly.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology