Femoral artery inflow in relation to external and total work rate at different knee extensor contraction rates

Author:

Osada Takuya12,Rådegran Göran1

Affiliation:

1. The Copenhagen Muscle Research Centre, University of Copenhagen, and Rigshospitalet, DK-2100 Copenhagen Ø, Denmark; and

2. Department of Preventive Medicine and Public Health, Tokyo Medical University, Tokyo 160-8402, Japan

Abstract

Whether limb blood flow is directly regulated to match the work rate, independent of the rate of contraction, remains elusive. This study therefore investigated the relationship between femoral arterial blood flow (FABF; Doppler ultrasound) and “external” (applied load) as well as “total” [external + “internal” (potential and kinetic energy changes of the moving lower leg)] work rate, during steady-state one-legged, dynamic, knee extensor exercise (1L-KEE) in the sitting position at different contraction rates. Ten subjects performed 1L-KEE at 30, 60, and 90 contractions/min (cpm) 1) at constant resistive loads of 0.2 and 0.5 kg inducing incremental external work rates ( study I) and 2) at different relative resistive loads inducing constant external work rates of 9 and 18 W ( study II). Moreover, 3) six subjects performed 1L-KEE at 60 and 100 cpm at incremental total work rates of 40, 50, 60, and 70 W ( study III). In study I, FABF increased ( P < 0.001) with increasing contraction frequency and external work rate, for each resistive load. In study II, FABF increased ( P < 0.001) with increasing contraction frequency for each constant external work rate. Of major importance in study III, however, was that FABF, although increasing linearly with the total work rate, was not different ( P= not significant) between contraction rates, at the total work rates of 40, 50, 60, and 70 W, respectively. Furthermore, FABF correlated linearly and positively with both the external and total work rate for each contraction frequency. In conclusion, the findings support the concept that leg blood flow during 1L-KEE in a normal knee extensor ergometer is matched directly in relation to the total work rate and metabolic activity, irrespective of the contraction frequency. The rate of contraction seems erroneously to influence the results only when it is related to the external work rate without taking into account the internal work component.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3