Application of muscle biopotential measurement for sustained, noninvasive blood glucose survey

Author:

Vol Alexander,Gribova Orna,Berman Sylvia,Siman-Tov Yariv,Efrati Shai

Abstract

Biopotential, the electric potential generated by living tissues, is affected by changes in extracellular electrolyte and glucose concentrations. We aimed to apply correlation between blood glucose concentrations (BGC) and biopotential of peripheral muscles for noninvasive blood glucose measurement. The study included 58 Wistar rats. In part of them, diabetes was induced by streptozotocin injection. Group 1, comprising 19 normal and 5 diabetic rats, received glucose-challenging protocol (intraperitoneal injection of 1 g/ml glucose). Group 2, 24 normal and 6 diabetic rats, received insulin-challenging protocol (three 30 IU insulin injections with 15-min intervals). Four control rats, group 3, were injected with 2-ml saline. BGC were measured by a standard ACCU-CHEK-Sensor Meter and compared with those estimated by biopotential sensor, further designated as GlucoSat, placed around proximal parts of the tails of the anaesthetized animals. GlucoSat results were calculated using the following biopotential equation: BGC( t) = k1 * F1( t) + k2 * F2( t) * k3 * F3( t) + k4, based on an experimental model involving estimation of pH, muscle metabolism, and tissue conductance, where t is time, k1–k4 are coefficients, and F1–F4 are functions. Mean biopotential system measured BGC was 181.7 ± 4.3 mg/dl, not differing statistically from 187.9 ± 4.3 mg/dl estimated by ACCU-CHEK. Pearson's correlation coefficient ( r2) was 0.961 ( P < 0.00001), indicating strong, direct correlation between the results. Within the nondiabetic group, r2 was 0.944 ( P < 0.00001), while, within the diabetic group, r2 was 0.974 ( P < 0.00001). No significant, adverse skin reactions were concomitantly observed in any experimental group. Biopotential measurements may be used for continuous, noninvasive estimation of changes in BGC. Further studies are needed to evaluate the applicability of this method to humans.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3