Frequency-based analysis of the early rapid filling pressure-flow relation elucidates diastolic efficiency mechanisms

Author:

Wu Yue,Kovács Sándor J.

Abstract

Stiffness- and relaxation-based diastolic function (DF) assessment can characterize the presence, severity, and mechanism of dysfunction. Although frequency-based characterization of arterial function is routine (input impedance, characteristic impedance, arterial wave reflection), DF assessment via frequency-based methods incorporating optimization/efficiency criteria is lacking. By definition, optimal filling maximizes (E wave) volume and minimizes “loss” at constant stored elastic strain energy (which initiates mechanical, recoil-driven filling). In thermodynamic terms, optimal filling delivers all oscillatory power (rate of work) at the lowest harmonic. To assess early rapid filling optimization, simultaneous micromanometric left ventricular pressure and echocardiographic transmitral flow (Doppler E wave) were Fourier analyzed in 31 subjects. A validated kinematic filling model provided closed-form expressions for E wave contours and model parameters. Relaxation-based DF impairment is indicated by prolonged E wave deceleration time (DT). Optimization was assessed via regression between the dimensionless ratio of 2nd (Q2) and 3rd flow harmonics (Q3) to the lowest harmonic (Q1), i.e., (Q2/Q1) or (Q3/Q1) vs. DT or c, the filling model’s viscosity/damping (energy loss) parameter. Results show that DT prolongation or increased c generated increased oscillatory power at higher harmonics (Q2/Q1 = 0.00091DT + 0.09837, r = 0.70; Q3/Q1 = 0.00053DT + 0.02747, r = 0.60; Q2/Q1 = 0.00614 c + 0.15527, r = 0.91; Q3/Q1 = 0.00396 c + 0.05373, r = 0.87). Because ideal filling is achieved when all oscillatory power is delivered at the lowest harmonic, the observed increase in power at higher harmonics is a measure of filling inefficiency. We conclude that frequency-based analysis facilitates assessment of filling efficiency and elucidates the mechanism by which diastolic dysfunction associated with prolonged DT impairs optimal filling.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司