A ventricular-vascular coupling model in presence of aortic stenosis

Author:

Garcia Damien,Barenbrug Paul J. C.,Pibarot Philippe,Dekker André L. A. J.,van der Veen Frederik H.,Maessen Jos G.,Dumesnil Jean G.,Durand Louis-Gilles

Abstract

In patients with aortic stenosis, the left ventricular afterload is determined by the degree of valvular obstruction and the systemic arterial system. We developed an explicit mathematical model formulated with a limited number of independent parameters that describes the interaction among the left ventricle, an aortic stenosis, and the arterial system. This ventricular-valvular-vascular (V3) model consists of the combination of the time-varying elastance model for the left ventricle, the instantaneous transvalvular pressure-flow relationship for the aortic valve, and the three-element windkessel representation of the vascular system. The objective of this study was to validate the V3 model by using pressure-volume loop data obtained in six patients with severe aortic stenosis before and after aortic valve replacement. There was very good agreement between the estimated and the measured left ventricular and aortic pressure waveforms. The total relative error between estimated and measured pressures was on average (standard deviation) 7.5% (SD 2.3) and the equation of the corresponding regression line was y = 0.99 x − 2.36 with a coefficient of determination r2 = 0.98. There was also very good agreement between estimated and measured stroke volumes ( y = 1.03 x + 2.2, r2 = 0.96, SEE = 2.8 ml). Hence, this mathematical V3 model can be used to describe the hemodynamic interaction among the left ventricle, the aortic valve, and the systemic arterial system.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Reference41 articles.

1. Symptomatic Aortic Stenosis

2. Comparison of valve resistance with effective orifice area regarding flow dependence

3. Briand M, Dumesnil JG, Kadem L, Tongue AG, Rieu R, Garcia D, and Pibarot P. Reduced systemic arterial compliance impacts significantly on LV afterload and function in aortic stenosis: implications for diagnosis and treatment. J Am Coll Cardiol. In press.

4. Validation of a new intraoperative technique to evaluate load-independent indices of right ventricular performance in patients undergoing cardiac operations

5. Hemodynamic stability of valve area, valve resistance, and stroke work loss in aortic stenosis: A comparative analysis

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Patient–Specific Immersed Finite Element–Difference Model of Transcatheter Aortic Valve Replacement;Annals of Biomedical Engineering;2022-10-20

2. New Evidence About Aortic Valve Stenosis and Cardiovascular Hemodynamics;High Blood Pressure & Cardiovascular Prevention;2022-04-19

3. Myocardial work and aorta stenosis simulation;Cardiovascular and Respiratory Bioengineering;2022

4. The Critical Role of Lumped Parameter Models in Patient-Specific Cardiovascular Simulations;Archives of Computational Methods in Engineering;2021-12-02

5. Ageing, Hypertension and Aortic Valve Stenosis: A Conscious Uncoupling;Heart, Lung and Circulation;2021-11