Preload-adjusted right ventricular maximal power: concept and validation

Author:

Schenk Soren,Popović Zoran B.,Ochiai Yoshie,Casas Fernando,McCarthy Patrick M.,Starling Randall C.,Kopcak Michael W.,Dessoffy Raymond,Navia Jose L.,Greenberg Neil L.,Thomas James D.,Fukamachi Kiyotaka

Abstract

Right ventricular (RV) maximal power (PWRmx) is dependent on preload. The objective of this study was to test our hypothesis that the PWRmx versus end-diastolic volume (EDV) relationship, analogous to the load-independent stroke work (SW) versus EDV relationship (preload-recruitable SW, PRSW), is linear, with the PWR x-axis intercept (V0PWR) corresponding to the PRSW intercept (V0SW). If our hypothesis is correct, the preload sensitivity of PWRmx could be eliminated by adjusting for EDV and V0PWR. Ten dogs were instrumented with a pulmonary flow probe, micromanometers, and RV conductance catheter. Data were obtained during bicaval occlusions under various conditions and fitted to PWRmx = a·(EDV − V0PWR)β, where a is the slope of the relationship. The PWRmx versus EDV relationship did not deviate from linearity (β = 1.09, P = not significant vs. 1), and V0PWR correlated with V0SW ( r = 0.93, P <0.0001). V0PRW was related to steady-state EDV and left ventricular end-diastolic pressure, allowing for estimation of V0PWR (V0Est) and single-beat PWRmx preload adjustment. Dividing PWRmx by the difference of EDV and V0PWR (PAMPV0PWR) eliminated preload dependency down to 50% of the baseline EDV. PWRmx adjustment using V0Est (PAMPV0Est) showed similar preload independency. Enhancing contractility increased PAMPV0PWR and PAMPV0Est from 176 ± 52 to 394 ± 205 W/ml × 104 and 145 ± 51 to 404 ± 261 W/ml × 104, respectively, accompanied by an increase of PRSW from 13.0 ± 4.5 to 29.7 ± 16.4 mmHg (all P <0.01). PAMPV0PWR and PAMPV0Est correlated with PRSW ( r = 0.85; r = 0.77; both P <0.001). Numerical modeling confirmed the accuracy of our experimental data. Thus preload adjustment of PWRmx should consider a linear PWRmx versus EDV relationship with distinct V0PWR. PAMPV0PWR is a preload-independent estimate of RV contractility that may eventually be determined noninvasively.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3