Measurement of aortic input impedance in rats

Author:

Mitchell G. F.1,Pfeffer M. A.1,Westerhof N.1,Pfeffer J. M.1

Affiliation:

1. Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115.

Abstract

Measurement of aortic input impedance in the rat is complicated by a high basal heart rate but is possible if appropriate compensation is made for frequency-dependent errors in modulus and phase resulting from analog filters in the equipment and from nonalignment of pressure and flow sensors. Because input impedance is a complex quantity, accurate values for both phase and modulus are required before meaningful interpretation of the data can be made. We measured aortic pressure and electromagnetic ascending aortic blood flow in mature, ether-anesthetized, open-chest male Wistar rats. Pressure and flow waveforms were averaged in the time domain and converted to Fourier series. Flow moduli were corrected for the measured frequency response of the flowmeter. Phase spectra were corrected by the classic frequency-domain and two new time-domain methods. Compensation for instrumentation errors was assessed at two different flowmeter filter settings in five animals. Reproducibility, variability, and the effects of vasoconstriction were assessed in 43 animals. Three methods of estimating characteristic impedance from the impedance spectra were evaluated and found to produce comparable results at baseline and following pharmacological elevation of blood pressure with graded methoxamine infusion. Physiologically equivalent values for phase, as assessed by comparing oscillatory power calculated from the impedance spectra, were obtained with each of the phase-correction techniques. The new time-domain methods facilitate the assessment of aortic input impedance in this small animal model because they do not require measurement of the spatial separation between pressure and flow transducers and pulse wave velocity in the proximal aorta.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3