Affiliation:
1. British Heart Foundation Cardiac Arrhythmia Research Group, Department of Physiology, Charing Cross and Westminster Medical School, London, United Kingdom.
Abstract
Electrical and mechanical alternans have often been found to coexist. However, the factors controlling their interdependence are not known. In this study we measure regional electrical and mechanical activity during mechanical alternans to investigate this relationship. Mechanical alternans was induced by rapid atrial pacing in 18 anesthetized, open-chest pigs. Regional segmental contraction and monophasic action potential were measured in three areas of left ventricle using epicardial tripodal strain gauges and suction electrodes. Electrical alternans always accompanied pulsus alternans. The phase of electrical alternans was not related to any measure of regional mechanical activity but did show a constant discordant relation to peak ventricular pressure. This suggested that mechanically dependent changes in action potential duration (mechanoelectric feedback) may be important in modulation electrical alternans. In support of this, pulsus alternans simulated by clamping the proximal aorta on alternate beats was associated with electrical alternans comparable to that produced with rapid atrial pacing. Mechanoelectric feedback modulates regional electrophysiology in the intact heart and may be important in the generation of electrical alternans.
Publisher
American Physiological Society
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology
Cited by