A transatrial pericardial access: lead placement as proof of concept

Author:

Kassab G. S.123,Svendsen M.4,Combs W.5,Choy J. S.1,Berbari E. J.1,Navia J. A.6

Affiliation:

1. Departments of 1Biomedical Engineering,

2. Surgery, and

3. Cellular and Integrative Physiology, Indiana University Purdue University Indianapolis, Indianapolis; and

4. Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana;

5. Medtronic, Minneapolis, Minnesota; and

6. Austral University, Buenos Aires, Argentina

Abstract

A safe, easy, and quick access into the pericardial space may provide a window for diagnostics and therapeutics to the heart. The objective of this study was to provide proof of concept for an engagement and access catheter that allows access to the pericardial space percutaneously. A multilumen catheter was developed to allow navigation and suction fixation to the right atrial appendage/wall in a normal swine model. Advancement through the multilumen catheter using a second catheter with a distal needle tip allows access to the pericardial space without pericardial puncture and advancement of a standard guide wire into the space. Navigation into the pericardial space was undertaken by fluoroscopy alone and was accomplished in 10 swine (5 acute and 5 chronic). As a specific application of this pericardial access method, a pacing lead was implanted on the epicardial surface. Five chronic swine experiments were conducted with successful pacing engagement verified by lead impedance and pacing threshold and sensing. Lead impedance exceeded 1,000 Ω preengagement and dropped by an average of 200 Ω upon implant (769 ± 498 Ω). Pacing thresholds at 0.4 ms ranged from ∼0.5 to 2.1 V acutely (1.03 ± 0.92 V). No cardiac effusion or tamponade was observed in any of the acute or chronic studies. The ability to engage, maintain, and retract the right atrial appendage/wall and to engage an epicardial lead was successfully demonstrated. These findings support the feasibility of safe access into the pericardial space in a normal swine model and warrant further investigations for clinical translation.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3