Spinotrapezius muscle microcirculatory function: effects of surgical exteriorization

Author:

Bailey Janet K.1,Kindig Casey A.1,Behnke Brad J.1,Musch Timothy I.1,Schmid-Schoenbein Geert W.2,Poole David C.1

Affiliation:

1. Departments of Kinesiology Anatomy and Physiology, Kansas State University, Manhattan, Kansas 66506-5602; and

2. Department of Bioengineering, University of California, San Diego, La Jolla, California 92093

Abstract

Intravital microscopy facilitates insights into muscle microcirculatory structural and functional control, provided that surgical exteriorization does not impact vascular function. We utilized a novel combination of phosphorescence quenching, microvascular oxygen pressure (microvascular Po 2), and microsphere (blood flow) techniques to evaluate static and dynamic behavior within the exposed intact (I) and exteriorized (EX) rat spinotrapezius muscle. I and EX muscles were studied under control, metabolic blockade with 2,4-dinitrophenol (DNP), and electrically stimulated conditions with 1-Hz contractions, and across switches from 21 to 100% and 10% inspired O2. Surgical preparation did not alter spinotrapezius muscle blood flow in either I or EX muscle. DNP elevated muscle blood flow ∼120% ( P < 0.05) in both I and EX muscles ( P> 0.05 between I and EX). Contractions reduced microvascular Po 2 from 30.4 ± 4.3 to 21.8 ± 4.8 mmHg in I muscle and from 33.2 ± 3.0 to 25.9 ± 2.8 mmHg in EX muscles with no difference between I and EX. In each O2condition, there was no difference (each P > 0.05) in microvascular Po 2 between I and EX muscles (21% O2: I = 37 ± 1; EX = 36 ± 1; 100%: I = 62 ± 5; EX = 51 ± 9; 10%: I = 20 ± 1; EX = 17 ± 2 mmHg). Similarly, the dynamic behavior of microvascular Po 2 to altered inspired O2 was unaffected by the EX procedure [half-time ( t 1/2) to 100% O2: I = 23 ± 5; EX = 23 ± 4; t 1/2 to 10%: I = 14 ± 2; EX = 16 ± 2 s, both P > 0.05]. These results demonstrate that the spinotrapezius muscle can be EX without significant alteration of microvascular integrity and responsiveness under the conditions assessed.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司