Influence of segmented vessel size due to limited imaging resolution on coronary hyperemic flow prediction from arterial crown volume

Author:

van Horssen P.1,van Lier M. G. J. T. B.1,van den Wijngaard J. P. H. M.1,VanBavel E.1,Hoefer I. E.2,Spaan J. A. E.1,Siebes M.1ORCID

Affiliation:

1. Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands; and

2. Department of Experimental Cardiology, Utrecht Medical Center, Utrecht, The Netherlands

Abstract

Computational predictions of the functional stenosis severity from coronary imaging data use an allometric scaling law to derive hyperemic blood flow (Q) from coronary arterial volume (V), Q = αVβ. Reliable estimates of α and β are essential for meaningful flow estimations. We hypothesize that the relation between Q and V depends on imaging resolution. In five canine hearts, fluorescent microspheres were injected into the left anterior descending coronary artery during maximal hyperemia. The coronary arteries of the excised heart were filled with fluorescent cast material, frozen, and processed with an imaging cryomicrotome to yield a three-dimensional representation of the coronary arterial network. The effect of limited image resolution was simulated by assessing scaling law parameters from the virtual arterial network at 11 truncation levels ranging from 50 to 1,000 μm segment radius. Mapped microsphere locations were used to derive the corresponding relative Q using a reference truncation level of 200 μm. The scaling law factor α did not change with truncation level, despite considerable intersubject variability. In contrast, the scaling law exponent β decreased from 0.79 to 0.55 with increasing truncation radius and was significantly lower for truncation radii above 500 μm vs. 50 μm ( P < 0.05). Hyperemic Q was underestimated for vessel truncation above the reference level. In conclusion, flow-crown volume relations confirmed overall power law behavior; however, this relation depends on the terminal vessel radius that can be visualized. The scaling law exponent β should therefore be adapted to the resolution of the imaging modality.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3