New double-tracer digital radiography for analysis of spatial and temporal myocardial flow heterogeneity

Author:

Matsumoto Takeshi1,Tachibana Hiroyuki1,Ogasawara Yasuo1,Kajiya Fumihiko1

Affiliation:

1. Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama 701-0192 Japan

Abstract

A new high-resolution digital radiographic technique based on the deposition of125I- and 3H-labeled desmethylimipramine (IDMI and HDMI, respectively) was developed for the assessment of spatial and temporal myocardial flow heterogeneity at a microvascular level. The density distributions of two tracers, or relative flow distributions, were determined by subtraction digital radiography using two imaging plates of different sensitivity. The regions resolved are comparable in size to vascular regulatory units (400 × 400 μm2). This method was applied to the measurement of within-layer myocardial flow distributions in Langendorff-perfused rabbit hearts. The validity of this method was confirmed by the strong correlation between regional densities of two tracers injected simultaneously ( r = 0.89 ± 0.03, n = 8). The temporal flow stability was evaluated by a 90-s continuous IDMI injection and subsequent bolus HDMI injection ( n = 8). Regional densities of the two tracers were fairly correlated ( r = 0.86 ± 0.03), indicating that the spatial pattern of flow distribution was stable even at a microvascular level over a 90-s period. The effect of microsphere embolization on the flow distribution was also investigated by the sequential injections of IDMI, 15-μm microspheres, and HDMI at 20-s intervals ( n = 8). Microembolization increased the coefficient of variation of tracer density from 19 to 25% ( P < 0.05), whereas the regional densities of two tracers were still correlated substantially, as in the case of no embolization ( r = 0.84 ± 0.06). Thus the microsphere embolization enhanced flow heterogeneity with increasing flow differences between control high-flow and control low-flow regions but rather maintained the pattern of flow distribution. In conclusion, double-tracer digital radiography will be a promising method for the spatial and temporal myocardial flow analysis at microvascular levels.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Fluorescence imaging to quantify the fluorescent microspheres in cardiac tissue;Journal of Biophotonics;2011-03-28

2. Spectral measurements of imaging plate backgrounds, alpha-particles and beta-particles;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2010-12

3. Microheterogeneity of regional myocardial blood flows in low-perfused rat hearts evaluated by double-tracer digital radiography;Applied Radiation and Isotopes;2007-08

4. Coronary microcirculation: Physiology and mechanics;Fluid Dynamics Research;2005-07

5. Pattern differences between distributions of microregional myocardial flows in crystalloid- and blood-perfused rat hearts;American Journal of Physiology-Heart and Circulatory Physiology;2004-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3