Adaptation of ventricular repolarization time following abrupt changes in heart rate: comparisons and reproducibility of repeated atrial and ventricular pacing

Author:

Axelsson Karl-Jonas12ORCID,Gransberg Lennart1,Lundahl Gunilla1,Vahedi Farzad12,Bergfeldt Lennart12ORCID

Affiliation:

1. Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

2. Department of Cardiology, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg Sweden

Abstract

During atrial pacing, the CL decreased on average 45% from mean (SD) 944 (120) to 518 (46) ms and QT decreased on average 18% from 388 (20) to 318 (17) ms. For QT, T90 End was 103 (24) s and 126 (15) s after start versus stop of atrial pacing; a difference of 24 (27) s ( P = 0.006). The response pattern was similar for τ but IR did not differ significantly between pacing start and stop. The response pattern was similar for QTpeak and also for QT and QTpeak following ventricular pacing start and stop. The coefficients of variation for repeated measures were 7%–21% for T90 End and τ. In conclusion, the adaptation of VR duration was significantly more rapid following increasing than decreasing HR and intraindividually a relatively reproducible process.

Funder

Swedish government and the county councils

Hjärt-Lungfonden

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献