Author:
Elharrar V.,Lovelace D. E.
Abstract
Automated analysis of intracellular action potentials from cardiac Purkinje fibers was implemented using a microcomputer system. A dual sampling rate was used during analog-to-digital conversion of action potentials recorded from stimulated fibers. The rapid phase of depolarization was sampled at 42.55 kHz. The repolarization and the diastolic phases were sampled at 1 kHz. The resting potential, action potential amplitude, conduction time, action potential duration measured at 50% and at 90% of repolarization, and the maximum upstroke velocity were obtained on-line. The digital form of the action potential was stored on cassette tape and a table containing the various measurements was assembled during the experiment. In unstimulated fibers, the time interval between consecutive action potentials was measured on-line along with the maximum diastolic potential, the action potential overshoot, and the slope of the diastolic depolarization.
Publisher
American Physiological Society
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献