Solving a century-old conundrum underlying cardiac force-length relations

Author:

Han June-Chiew1ORCID,Pham Toan12ORCID,Taberner Andrew J.13ORCID,Loiselle Denis S.12ORCID,Tran Kenneth1ORCID

Affiliation:

1. Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand

2. Department of Physiology, University of Auckland, Auckland, New Zealand

3. Department of Engineering Science, University of Auckland, Auckland, New Zealand

Abstract

In the late 19th century, Otto Frank presented a diagram (Frank O. Z Biol 37: 483–526, 1899) showing that cardiac end-systolic pressure-volume relations are dependent on the mode of contraction: one for isovolumic contractions that locate above that for afterloaded ejecting contractions. Conflicting results to Frank’s have been subsequently demonstrated in various species, both within and among preparations, ranging from the whole hearts to single myocytes, showing a single pressure-volume or force-length relation that is independent of the mode of contraction. Numerous explanations for these conflicting results have been proposed but are mutually contradictory and hence unsatisfying. The present study aimed to explore how these conflicting findings can be reconciled. We thus explored the cardiac force-length relation across a wide spectrum of both preloads and afterloads, encompassing the physiological working range. Experiments were performed using isolated ventricular trabeculae at physiological temperature and stimulus frequency. The force-length relation obtained from isometric contractions was indeed located above a family of those obtained from shortening contractions. Low preload conditions rendered the relation contraction mode independent. High afterload conditions also showed a comparable effect. Our exploration allowed us to reveal the loading conditions that can explain the apparent single, contraction mode-independent, force-length relation that is in contrast with that presented by Frank. Resolving this century-old cardiac conundrum highlights the caution that must be taken when using the end-systolic force-length relation to illustrate as well as to understand the concepts of the Frank-Starling law of the heart, “potential energy,” and cardiac contractility. NEW & NOTEWORTHY Our exploration of the cardiac force-length relation under wide ranges of preload and afterload has allowed us to reconcile conflicting results in the literature regarding its length dependency. We show that the relation is dependent on the mode of contraction but can appear to be otherwise under certain conditions. This finding highlights the need for caution when using the force-length relation to understand key concepts in cardiac physiology.

Funder

Royal Society of New Zealand | Marsden Fund (Royal Society of New Zealand Marsden Fund)

National Heart Foundation of New Zealand

Manatu Hauora | Health Research Council of New Zealand (HRC)

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3