Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris

Author:

Kleinbongard Petra1,Baars Theodor2,Möhlenkamp Stefan3,Kahlert Philipp2,Erbel Raimund2,Heusch Gerd1

Affiliation:

1. Institut für Pathophysiologie, Universitätsklinikum Essen, Essen, Germany;

2. Klinik für Kardiologie, Universitätsklinikum Essen, Essen, Germany; and

3. Bethanien-Krankenhaus Moers, Moers, Germany

Abstract

Stent implantation into atherosclerotic coronary arteries releases particulate debris and soluble substances that contribute to impaired microvascular perfusion. Here we addressed the potential for microvascular obstruction in patients with stenotic native right coronary arteries (nRCA) compared with saphenous vein grafts on right coronary arteries (SVG-RCA). We enrolled symptomatic, male patients with stable angina pectoris and a flow-limiting stenosis in their nRCA or SVG-RCA ( n = 18/18). Plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation under protection with a distal occlusion/aspiration device and divided into particulate debris and plasma. The release of catecholamines, endothelin, serotonin, thromboxane B2, and tumor necrosis factor-α was measured. The response of rat mesenteric arteries with intact (+E) and denuded (−E) endothelium to aspirate plasma (without and with selective endothelin receptor blockade) was normalized to that by potassium chloride (KClmax = 100%). Plaque volume and composition were not different between nRCA and SVG-RCA. There was less particulate debris (65 ± 8 vs. 146 ± 23 mg; P < 0.05) and more endothelin release (5.8 ± 0.8 vs. 1.3 ± 0.7 pg/ml; P < 0.05) in nRCA than in SVG-RCA, whereas the release of the other mediators was not different. Aspirate from nRCA induced stronger vasoconstriction than that from SVG-RCA [nRCA, 78 ± 6% (+E)/84 ± 5% (−E); SVG-RCA, 59 ± 6% (+E)/68 ± 3% (−E); P < 0.05 nRCA vs. SVG-RCA], which was attenuated by a nonspecific endothelin and a specific endothelin receptor A antagonist. Thus coronary aspirate from stented nRCA is characterized by less debris but more endothelin and stronger vasoconstrictor response than that from SVG-RCA.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3