Comparison of noise-power spectrum and modulation-transfer function for CT images reconstructed with iterative and deep learning image reconstructions: An initial experience study

Author:

Setiawan Adiwasono M. B.1,Anam Choirul1ORCID,Hidayanto Eko1,Sutanto Heri1,Naufal Ariij1,Dougherty Geoff2

Affiliation:

1. 1 Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University , Jl. Prof. Soedarto SH, Tembalang, Semarang , Central Java , Indonesia

2. 2 Department of Applied Physics and Medical Imaging, California State University Channel Islands , Camarillo CA , USA

Abstract

Abstract Introduction Deep learning image reconstruction (DLIR) is a very recent image reconstruction method that is already available for commercial use. We evaluated the quality of DLIR images and compared it to the quality of images from the latest adaptive statistical iterative reconstruction (ASIR-V) algorithm in terms of noise-power spectrum (NPS) and modulation-transfer function (MTF). Methods We scanned a Revolution QA phantom (GE Healthcare, USA) and a 20 cm water phantom (GE Healthcare, USA) with our 512 multi-slice computed tomography (CT) scanner. Images of the tungsten wire within the Revolution QA phantom were reconstructed with a 50 mm field of view (FOV). The images were reconstructed with various ASIR-V strengths (i.e. 0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100%) and DLIRs (i.e. low, medium, and high) to assess the MTF. The images from the 20 cm water phantom were reconstructed with the same configuration to assess the NPS. Results The MTF was similar for both reconstruction algorithms of DLIR and ASiR-V. The peak frequency (fp) of the DLIR low was comparable to that from ASIR-V at 50, 60, 70%; the DLIR medium was comparable to ASIR-V at 80%; and the DLIR high was comparable to ASIR-V at 100%. The average frequency (fA) of the DLIR low was comparable to that from ASIR-V at 40%; the DLIR medium was comparable to ASIR-V at 50%; and the DLIR high was comparable to ASIR-V at 70%. Both the DLIR and ASIR-V were able to reduce noise, but they had a different texture. Conclusions The noise in the DLIR images was more homogenous at high and low frequencies, while in the ASIR-V images, the noise was more concentrated at high frequencies. The MTF was similar for both reconstruction algorithms. The DLIR method showed a better noise reduction than the ASIR-V reconstruction.

Publisher

Walter de Gruyter GmbH

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3