EPID – a useful interfraction QC tool

Author:

Klimas Aleksandra12,Grządziel Aleksandra3,Plaza Dominika3,Bekman Barbara3,Woźniak Bożena4,Dolla Łukasz3,Osewski Wojciech5,Paściak Paweł3,Wendykier Jacek3,Ślosarek Krzysztof3

Affiliation:

1. Medical Physics Department , Zagłębiowskie Oncology Center , Dąbrowa Górnicza , Poland

2. Medical Physics Department, Institute of Physics , University of Silesia , Chorzów , Poland

3. Radiotherapy Planning Department , Maria Sklodowska-Curie Institute – Oncology Center Gliwice Branch , Gliwice , Poland

4. Medical Physics Department , Maria Sklodowska-Curie Institute – Oncology Center Gliwice Branch , Gliwice , Poland

5. IT Department , Maria Sklodowska-Curie Institute – Oncology Center Gliwice Branch , Gliwice , Poland

Abstract

Abstract Biomedical accelerators used in radiotherapy are equipped with detector arrays which are commonly used to obtain the image of patient position during the treatment session. These devices use both kilovolt and megavolt x-ray beams. The advantage of EPID (Electronic Portal Imaging Device) megavolt panels is the correlation of the measured signal with the calibrated dose. The EPID gives a possibility to verify delivered dose. The aim of the study is to answer the question whether EPID can be useful as a tool for interfraction QC (quality control) of dose and geometry repeatability. The EPID system has been calibrated according to the manufacturer’s recommendations to obtain a signal and dose values correlation. Initially, the uncertainty of the EPID matrix measurement was estimated. According to that, the detecting sensitivity of two parameters was checked: discrepancies between the planned and measured dose and field geometry variance. Moreover, the linearity of measured signal-dose function was evaluated. In the second part of the work, an analysis of several dose distributions was performed. In this study, the analysis of clinical cases was limited to stereotactic dynamic radiotherapy. Fluence maps were obtained as a result of the dose distribution measurements with the EPID during treatment sessions. The compatibility of fluence maps was analyzed using the gamma index. The fluence map acquired during the first fraction was the reference one. The obtained results show that EPID system can be used for interfraction control of dose and geometry repeatability.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Portal dosimetry in radiotherapy repeatability evaluation;Journal of Applied Clinical Medical Physics;2020-12-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3