Determination of DQE as a quantitative assessment of detectors in digital mammography: Measurements and calculation in practice

Author:

Wysocka-Rabin Anna1,Dobrzyńska Magdalena1,Pasicz Katarzyna2,Skrzyński Witold2,Fabiszewska Ewa2

Affiliation:

1. Particle Acceleration Physics and Technology Division, National Centre for Nuclear Research (NCNR) , Poland

2. Medical Physics Department , Maria Sklodowska-Curie National Research Institute of Oncology (MSCNRIO) , Poland

Abstract

Abstract Introduction: Advances in digital detector technology and methods of image presentation in digital mammography now offer the possibility of implementing mathematical assessment methods to quantitative image analysis. The aim of this work was to develop new software to simplify the application of the existing international standard for DQE in digital mammography and show in detail how it can be applied, using a Siemens Mammomat Inspiration as a model. Material and methods: Consistent with the IEC standard a 2 mm Al filter at the tube exit and images in DICOM format as raw data, without applying any additional post-processing were used. Measurements were performed for W/Rh anode/filter combination and different tube voltage values (26 ÷ 34 kV) without any anti-scatter grid. To verify new software doses ranging from 20-600 µGy were used in measurements. Exposure (air kerma) was measured using a calibrated radiation meter (Piranha Black 457, RTI Electronics AB, Sweden). MTF was determined, using an edge test device constructed specifically for this work. Results: It has been demonstrated that with the new software the DQE can be measured with the accuracy required by the international standard IEC 62220-1-2. DQE has been presented as a function of spatial frequency for W/Rh anode/filter combination and different tube voltage. Conclusions: New software was used successfully to analyze image quality parameters for the Siemens Mammomat Inspiration detector. This was done on the basis of an internationally accepted methodology. In the next step, mammographs with different detector types can be compared.

Publisher

Walter de Gruyter GmbH

Reference41 articles.

1. 1. Narodowy Program Zwalczania Chorób Nowotworowych. http://profilaktykaraka.coi.waw.pl/, access: February 2020 [in Polish]

2. 2. Didkowska J, Wojciechowska U. Zachorowania i zgony na nowotwory złośliwe w Polsce. Krajowy Rejestr Nowotworów, Narodowy Instytut Onkologii im. Marii Skłodowskiej-Curie – Państwowy Instytut Badawczy. http://onkologia.org.pl/k/epidemiologia/, access: April 2020 [in Polish]

3. 3. Dz.U. 2017 poz. 884. Obwieszczenie Ministra Zdrowia z dnia 3 kwietnia 2017 r. w sprawie ogłoszenia jednolitego tekstu rozporządzenia Ministra Zdrowia w sprawie warunków bezpiecznego stosowania promieniowania jonizującego dla wszystkich rodzajów ekspozycji medycznej [in Polish]

4. 4. American College of Radiology. Mammography Quality Control Manual. 1999

5. 5. Huda W, Sajewicz AM, Ogden KM, Scalzetti EM, Dance DR. How Good Is the ACR Accreditation Phantom for Assessing Image Quality in Digital Mammography. Acad Radiol. 2002;9(7):764–772. https://doi.org/10.1016/S1076-6332(03)80345-8

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3