Quantitative and dosimetric analysis for treating synchronous bilateral breast cancer using two radiotherapy planning techniques

Author:

Mermut Özlem1,Ata Aysun Ozsoy2,Trabulus Didem Can3

Affiliation:

1. Department of Radiation Oncology , University of Health Sciences Istanbul Training and Research Hospital , Turkey

2. Department of Radiation Oncology, MNT Health Services Medical Physicist , University of Health Sciences Istanbul Training and Research Hospital , Turkey

3. Clinic of General Surgery , University of Health Sciences Istanbul Training and Research Hospital , Turkey

Abstract

Abstract Objective: We compared mono-isocenter and dual-isocenter plans in synchronous bilateral breast cancer (SBBC), which is defined as tumours occurring simultaneously in both breasts, and evaluated the effects of these differences in plans on organs-at-risk (OARs). Materials and methods: We evaluated 10 women with early stage, nod negative (Tis-2N0M0) SBBC. The treatment dose was determined to be 50 Gy. We used mean dose and VXGy to evaluate the OARs. To evaluate the effectiveness of treatment plans, Homogeneity index (HI), conformity index (CI) and sigma index (SI) and monitor units (MU) of monoisocenter (MIT) and dual-isocenter (DIT) plans were compared. During bilateral breast planning, for the single-centre plan, the isocenter was placed at the center of both breasts at a depth of 3-4 cm. For the two-center plan, dual-isocenters were placed on the right and left breasts. Results: No significant difference between the techniques in terms of the scope of the target volume was observed. Statistically significant results were not achieved in MIT and DIT plans for OARs. Upon comparing MIT and DIT, the right-side monitor unit (MU) value in DIT (p = 0.011) was statistically significantly lower than that in MIT. Upon comparing right-left side MIT and DIT, the MU value (p = 0.028) was significantly lower in DIT than MIT. Conclusion: SBBC irradiation is more complex than unilateral breast radiotherapy. No significant difference between both techniques and OARs was observed. However, we recommend MIT as a priority technique due to the ability to protect OARs, ease of administration during treatment, and the fact that the patient stays in the treatment unit for a shorter period of time.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3