Local diagnostic reference levels in diagnostic and therapeutic pediatric cardiology at a specialist pediatric hospital in South Africa

Author:

Mbewe Jonathan1ORCID,Mjenxane Thembisa2

Affiliation:

1. Division of Medical Physics, Groote Schuur Hospital / University of Cape Town , South Africa

2. Department of Radiology , Red Cross War Memorial Children’s Hospital , South Africa

Abstract

Abstract Introduction: Children may be at a higher risk of experiencing the detrimental effects of ionizing radiation arising from medical radiation imaging. Dose optimisation is therefore recommended to provide assurance that their exposure is as low as reasonably achievable. To this end, periodic assessment of dose levels and establishment of Local Diagnostic Reference Levels (LDRLs) in medical facilities is necessary. There is a general paucity in the literature of data pertaining to dose levels in pediatric interventional radiology. This study establishes LDRLs in diagnostic and therapeutic heart catheterization procedures at a specialist pediatric hospital in a resource constrained country. Material and methods: Dose indicators from actual patient procedures were collected from the archive and analyzed retrospectively to determine the median, 25th, and 75th percentiles of the total Air Kerma Area Product (KAP), Cumulative Air Kerma (CAK), total Fluoroscopy Time (FT), and a total number of Cine Images (CI) of selected interventional procedures. The dose indicators were also age-stratified into five age groups defined by the International Commission on Radiation Protection publication 135. The results were compared to values available from similar studies in the literature to benchmark our dose levels. Local Dose Reference Levels were set as the 75th percentile values. Results: For diagnostic procedures (n = 80), the 75th percentiles of KAP, CAK, FT, and CI were 4.0 Gy·cm2, 31.5 mGy, 14.3 min, and 315 frames, respectively and 3.2 Gy·cm2, 30.5 mGy, 17.5 min, and 606 frames, respectively for therapeutic procedures (n = 143). Conclusions: The LDRLs from this study did not vary significantly from those published in the literature, suggesting that practices at our center were comparable to international norms. Regular reviews of the LDRLs must be conducted to check that the dose levels do not deviate considerably.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3