Effective atomic number and photon buildup factor of bismuth doped tissue for photon and particles beam interaction

Author:

Srinivasan K12,Samuel E James Jabaseelan1

Affiliation:

1. Department of Radiotherapy , Sterling Ramkrishna speciality Hospitals , Gandhidham , Gujarat , India

2. School of advanced sciences , VIT University , Vellore , Tamilnadu , India

Abstract

Abstract Introduction: The doping of high Z nanoparticles into the tumor tissue increases the therapeutic efficiency of radiotherapy called nanoparticle enhanced radiotherapy (NERT). In the present study, we are identifying the effective types of radiation and effective doping concentration of bismuth radiosensitizer for NERT application by analyzing effective atomic number (Zeff) and photon buildup factor (PBF) of bismuth (Bi) doped soft tissue for the photon, electron, proton, alpha particle, and carbon ion interactions. Material and methods: The direct method was used for the calculation of Zeff for photon and electron beams (10 keV-30 MeV). The phy-X/ZeXTRa software was utilized for the particle beams such as proton, alpha particle, and carbon ions (1-15 MeV). Bismuth doping concentrations of 5, 10, 15, 20, 25 and 30 mg/g were considered. The PBF was calculated over 15 keV-15 MeV energies using phy-X/PSD software. Results: The low energy photon (<100 keV) interaction with a higher concentration of Bi dopped tissue gives the higher values of Zeff. The Zeff increased with the doping concentration of bismuth for all types of radiation. The Zeff was dependent on the type of radiation, the energy of radiation, and the concentration of Bi doping. The particle beams such as electron, proton, alpha particle, and carbon ion interaction gives the less values of Zeff has compared to photon beam interaction. On the other hand, the photon buildup factor values were decreased while increasing the Bi doping concentration. Conclusions: According to Zeff and PBF, the low energy photon and higher concentration of radiosensitizer are the most effective for nanoparticle enhanced radiotherapy application. Based on the calculated values of Zeff, the particle beams such as electron, proton, alpha particle, and carbon ions were less effective for NERT application. The presented values of Zeff and PBF are useful for the radiation dosimetry in NERT.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3