GTV volume estimation using different mode of computer tomography for lung tumors in stereotactic body radiation therapy

Author:

Lingaiah Ramaa1,Ali Md Abbas2,Kulsum Ummay2,Muneem Muhtasim Aziz3,Mani Karthick Raj3,Ahmed Sharif3,Rahman Md. Shakilur4,Salahuddin M1

Affiliation:

1. Department of Physics , Jahangirnagar University , Savar, Dhaka - 1342 , Bangladesh

2. Department of Medical Physics and Biomedical Engineering , Gono Bishwabidyalay, Savar, Dhaka , Bangladesh

3. Department of Radiation Oncology , United Hospital, Dhaka , Bangladesh

4. Secondary Standard Dosimetry Laboratory , Institute of Nuclear Science and Technology, Bangladesh Atomic Energy Commission , Savar, Dhaka , Bangladesh

Abstract

Abstract Aim: To estimate the Gross Tumor Volume (GTV) using different modes (axial, helical, slow, KV-CBCT & 4D-CT) of computed tomography (CT) in pulmonary tumors. Materials & Methods: We have retrospectively included ten previously treated case of carcinoma of primary lung or metastatic lung using Stereotactic Body Radiation Therapy (SBRT) in this study. All the patients underwent 4 modes of CT scan Axial, Helical, Slow & 4D-CT using GE discovery 16 Slice PET-CT scanner and daily KV-CBCT for the daily treatment verification. For standardization, all the patients underwent different modes of scan using 2.5 mm slice thickness, 16 detectors rows and field of view of 400mm. Slow CT was performed using axial mode scan by increasing the CT tube rotation time (typically 3 – 4 sec.) as per the breathing period of the patients. 4D-CT scans were performed and the entire respiratory cycle was divided into ten phases. Maximum Intensity Projections (MIP), Minimum Intensity Projections (MinIP) and Average Intensity Projections (AvIP) were derived from the 10 phases. GTV volumes were delineated for all the patients in all the scanning modes (GTVAX - Axial, GTVHL - Helical, GTVSL – Slow, GTVMIP -4DCT and GTVCB – KV-CBCT) in the Eclipse treatment planning system version 11.0 (M/S Varian Medical System, USA). GTV volumes were measured, documented and compared with the different modes of CT scans. Results: The mean ± standard deviation (range) for MIP, slow, axial, helical & CBCT were 36.5 ± 40.5 (2.29 – 87.0), 35.38 ± 39.52 (2.1 – 82), 31.95 ± 37.29 (1.32 – 66.9), 28.98 ± 33.36 (1.01 – 65.9) & 37.16 ± 42.23 (2.29 – 92). Overall underestimation of helical scan and axial scan compared to MIP is 21% and 12.5%. CBCT and slow CT volume has a good correlation with the MIP volume. Conclusion: For SBRT in lung tumors better to avoid axial and helical scan for target delineation. MIP is a still a golden standard for the ITV delineation, but in the absence of 4DCT scanner, Slow CT and KV-CBCT data may be considered for ITV delineation with caution.

Publisher

Walter de Gruyter GmbH

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3