Determination of the CTV-PTV margin for prostate cancer radiotherapy depending on the prostate gland positioning control method

Author:

Sobajtis Aleksandra1,Kukołowicz Paweł2

Affiliation:

1. Medical Physics Department , University Hospital , Zyty 26 , Zielona Góra , Poland

2. Medical Physics Department , Center of Oncology , W. K. Roentgena 5 , Warsaw , Poland

Abstract

Abstract Objective: The objective of the study was to determine the correct CTV-PTV margin, depending on the method used to verify the PG position. In the study, 3 methods of CBCT image superimposition were assessed as based on the location of the prostate gland (CBCT images), a single gold marker, and pubic symphysis respectively. Materials and methods: The study group consisted of 30 patients undergoing irradiation therapy at the University Hospital in Zielona Góra. The therapy was delivered using the VMAT (Volumetric Modulated Arc Therapy) protocol. CBCT image-based superimposition (prostate-based alignment) was chosen as the reference method. The uncertainty of the PG positioning method was determined and the margin to be used was determined for the CBCT-based reference method. Then, changes in the position of the prostate gland relative to these determined using the single marker and pubic symphysis-based methods were determined. The CTV-PTV margin was calculated at the root of the sum of the squares for the doubled value of method uncertainty for the CBCT image-based alignment method and the value of the difference between the locations of planned and actual isocenters as determined using the method of interest and the CBCT-based alignment method for which the total number of differences accounted for 95% of all differences. Results: The CTV-PTV margins to be used when the prostate gland is positioned using the CBCT imaging, single marker, and pubic symphysis-based methods were determined. For the CBCT-based method, the following values were obtained for the Vrt, Lng, and Lat directions respectively: 0.43 cm, 0.48 cm, 0.29 cm. For the single marker-based method, the respective values were 0.7 cm, 0.88 cm, and 0.44 cm whereas for the pubic symphysis-based method these were 0.65 cm, 0.76 cm, and 0.46 cm. Conclusions: Regardless of the method, the smallest margin values were obtained for the lateral direction, with the CBCT-based method facilitating the smallest margins to be used. The largest margins were obtained using the single marker-based alignment method.

Publisher

Walter de Gruyter GmbH

Reference29 articles.

1. 1. Cuzick J, Thorat M, Andriole G, et al. Prevention and Early Detection of Prostate Cancer. Lancet Oncol. 2014 Oct; 15(11): e484– e492. doi: 10.1016/S1470-2045(14)70211-6

2. 2. Khullar K, Parikh R. The role of radiotherapy in metastatic prostate cancer. Am J Clin Exp Urol. 2019; 7(2): 92–97.

3. 3. Byrne T. A Review of Prostate Motion With Considerations for the Treatment of Prostate Cancer. Med Dosim. Fall 2005; 30(3):155-61. doi: 10.1016/j.meddos.2005.03.005.

4. 4. Gawlik – Jakubczak T, Matuszewski M. Fiducial markers in the treatmentof prostate cancer: technique and short term observation. Oncology in Clinical Practice. 2015; Vol. 11, No. 6, 295–299.

5. 5. Piotrowski T. Wybrane zagadnienia dotyczące planowania leczenia w radioterapii. Wielkopolskie Centrum Onkologii.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3