The influence of the used applicators on organ and target doses for cervical cancer patients treated with HDR brachytherapy

Author:

Pszczółkowska Beata1,Bijok Michał2,Brzozowska Beata1

Affiliation:

1. Biomedical Physics Division , University of Warsaw, Faculty of Physics , Poland

2. Department of Medical Physics , The Maria Sklodowska-Curie National Research Institute of Oncology , Poland

Abstract

Abstract Introduction: The aim of this work was to study the influence of the applicators used for cervical cancer patients treated with high dose-rate brachytherapy (HDR-BT) in the Maria Sklodowska-Curie National Research Institute of Oncology in Warsaw, Poland on doses in the tumour volumes and organs at risk. Material and methods: The treatment was carried out using Iridium-192 in 4 fractions (7.5 Gy each) given in weekly intervals. Two types of applicators were used for comparison: fletcher and ring. The standard dose distribution parameters, read from the system Oncentra Brachy (version 4.5, Elekta), for bladder, rectum, and sigmoid (D2 cc) and tumour (HRCTV D100, D98, D90) were studied. Patients were divided into two groups (240 treatment plans) depending on the type of applicator used and into four groups according to the tumour volumes (HR-CTV < 25 cm3 or HR-CTV ≥ 25 cm3). The collected data were analysed using the PQStatSoftware (version 1.8.2). Results: The treatment plans prepared with all types of applicators fulfil the dose distribution requirements, however, the dose delivered to the tumour using the ring applicator was found to be the highest. For the bladder and sigmoid the optimal dose distribution was obtained when using the fletcher applicator, while for the rectum the ring applicator gave the smallest dose value. The D2 cc parameter for sigmoid obtained for fletcher treatment has smaller values in the case of patients with small tumour volume and for this type of applicator was observed a statistically significant difference when compared with the ring. Conclusions: The ring applicator gives the optimal parameters of the dose distribution independently on the tumour volume with respect to the fletcher applicator, which is however more often used in clinical practice.

Publisher

Walter de Gruyter GmbH

Reference18 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3