Glucose meters: What’s the laboratory reference glucose?

Author:

Carta Mariarosa,Giavarina Davide,Paternoster Andreina,Bonetti Graziella

Abstract

SummaryBackgroundThe accuracy of glucose meters is evaluated by comparing their results with those from a reference laboratory glucose analyser. The main scientific societies recommend the use of a prompt glycolysis inhibitor such as citrate for an accurate glucose determination. In the present preliminary study, we discuss the bias between capillary and plasma glucose measured concentrations, determined in two Italian clinical laboratories, using tubes containing an NaF and citrate mixture in liquid and granular form.Methods139 volunteers in whom 75 g OGTT was requested were recruited. Basal capillary glucose was determined using Abbott FreeStyle Precision Neo in Brescia (n=63), while clinical laboratory reference P-glucose was determined using tubes containing NaF/K3EDTA and liquid NaF/Na2EDTA/citrate. Basal capillary glucose was determined using a Roche Cobas Accu-Chek Inform II in Vicenza (n=76), while P-glucose was determined using tubes containing NaF/K2Ox and NaF/Na2EDTA/citrate in granulated form. Reference P-glucose was determined with a hexokinase method on Dimension Vista systems. Differences between capillary and reference P-glucose were evaluated according to ADA/ISO 15197:2013 specifications.Results96.82% and 97.37% of capillary determinations were within specifications when liquid and granular citrate mixture tubes were used, respectively. Conversely, only 73.02% and 80.26% of determinations were within criteria using NaF.ConclusionsIt’s important to know what is the laboratory reference glucose in evaluating glucose meters’ accuracy. The evaluation of glucometers’ accuracy with respect to a reference laboratory may be wrong if tubes containing only NaF are used due to in vitro glycolysis. Only tubes containing citrate mixture permit the correct evaluation of glucose meters’ accuracy.

Publisher

Centre for Evaluation in Education and Science (CEON/CEES)

Reference36 articles.

1. Sodium fluoride: an ineffective inhibitor of glycolysis;Ann Clin Biochem,2013

2. Validity and Reliability of a Glucose Meter Against Industry Reference Standards;Journal of Diabetes Science and Technology,2014

3. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis;Biochem Med,2016

4. Effectiveness of sodium fluoride as a preservative of glucose in blood;Clin Chem,1989

5. Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results;Clinical Biochemistry,2017