An evaluation of concordance between linear measurements obtained from conventional, digital and reconstructed three-dimensional printed orthodontic models: An in vitro study

Author:

Shetty Shravan1,Natarajan Srikant2,Nambiar Supriya1,Shetty Prithvi3,Chengappa Kavery4,Shetty Mukul5

Affiliation:

1. Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences Mangalore , Manipal Academy of Higher Education , Manipal , Karnataka , India

2. Department of Oral Pathology and Microbiology , Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education , Manipal , Karnataka , India

3. Department of Public Health Dentistry , A.J. Institute of Dental Sciences , N.H.17, Kuntikana , Mangalore , Karnataka , India

4. Department of Public Health Dentistry, Manipal College of Dental Sciences Mangalore , Manipal Academy of Higher Education , Manipal , Karnataka , India

5. Department of Orthodontics and Dentofacial Orthopedics, A B Shetty Memorial Institute of Dental Sciences ; NITTE Deemed to be University , Mangalore , Karnataka , India

Abstract

Abstract Objective: To evaluate the potential use of digital and reconstructed three-dimensional printed models as an alternative to conventional plaster models by assessing the accuracy of their linear measurements. Methodology: Pre-treatment plaster models of 45 patients were selected from the archives of the Department of Orthodontics. Each physical plaster model was scanned and digitized using a three-dimensional (3D) laser surface scanning system (inEOS X5, Dentsply Sirona, Bensheim, Germany). The scanned STL files were later used to reconstruct models by 3D printing using Figure4® standalone 3D printer (3D systems, Rock Hill, South Carolina). Measurements of teeth 11 and 16, the transverse width of the upper jaw between the first molars (MM - intermolar width) and canines (CC - intercanine width) were done manually using a digital vernier caliper (Mitutoyo, Kawasaki, Japan), and the CAD Assistant software (Open cascade, Guyancourt, France). Intra examiner data, Intraobserver variability, and measurement accuracy were evaluated using Intraclass Correlation Coefficient (ICC) analysis was done using SPSS 20.0. Results: The intraclass correlation coefficients were >0.8 indicating high reproducibility and reliability. Significant differences were found between the physical and the digital models but to a small proportion which were deemed not clinically relevant. Conclusion: Both the digital models and reconstructed three-dimensional printed models using Figure4® technology were clinically permissible in terms of accuracy and reproducibility. The digital storage, transmission, and treatment planning in an environmentally friendly manner should promote digital over conventional records.

Publisher

Walter de Gruyter GmbH

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3