Analysis of Operation Parameters of Fish Refrigeration by Exergy Analysis. Case Study

Author:

Terehovics Edvins1,Veidenbergs Ivars1,Blumberga Dagnija1

Affiliation:

1. Institute of Energy Systems and Environment , Riga Technical University , Azenes iela 12/1, Riga , LV-1048 , Latvia

Abstract

Abstract Unlike energy efficiency, in terms of exergy efficiency it is possible to compare the existing operation of an energy conversion system with the ideal operation. Exergy loses and exergy destruction make it possible to identify the shortcomings of an existing system, which should be improved immediately. With exergy analysis, it is possible to identify the priority actions that need to be taken in order to improve the functioning of the system: greater exergy loss prevention is the highest priority. Energy efficiency refers to the useful work and investments needed to obtain useful work and investments needed to obtain energy efficiency; this is important to some extent, but the effectiveness of exergy makes it possible to compare system performance with the ideal. Results shows that the highest exergy destruction of a single-stage compressor refrigeration system from all working condition is found when ambient temperature and freezer temperature difference is 10 ºC, pressure in compressor is 0.62 MPa, ammonia temperature after compressor is 90 ºC, total exergy destruction of single-stage compressor refrigeration system 97.84 kW. The highest exergy efficiency of a single-stage compressor refrigeration system from all the working conditions is found when ambient temperature and freezer temperature difference is 39 ºC, pressure in compressor is 0.45 MPa, ammonia temperature after compressor is 128 ºC, exergy efficiency of a single-stage compressor refrigeration system is 59.76 %. The highest total exergy destruction of a two-stage compressor refrigeration system from among all the working conditions is found to be when the ambient temperature and freezer temperature difference is at 13 ºC, pressure in compressor 0.44 MPa, ammonia temperature after compressor 76 ºC, total exergy destruction 83.86 kW. The highest exergy efficiency of a two-stage compressor refrigeration system from among all the working conditions is found to be at an ambient temperature and freezer temperature difference of 39 ºC, pressure in compressor 0.56 MPa, ammonia temperature after compressor 92 ºC, exergy efficiency 53.55 %.

Publisher

Walter de Gruyter GmbH

Subject

General Environmental Science,Renewable Energy, Sustainability and the Environment

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Fish Processing Efficiency Ranking;Environmental and Climate Technologies;2020-11-01

2. Energy Efficiency Improvement in Thawing;Environmental and Climate Technologies;2020-09-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370