Affiliation:
1. The Swedish School of Textiles , University of Borås Allégatan 1 , Borås , Sweden
Abstract
Abstract
Every year, approximately 3,000 people in Sweden undergo amputation of a body part. The use of a prosthesis can greatly improve the quality of life for these people. To improve the fit and comfort of a prosthesis, a sock is used as an interface between the prosthesis socket and the stump. A three-dimensional (3D) body scanner can be used to take measurements that are used to produce individualized socks that improve fit and comfort. The standardized method for taking measurements with a 3D body scanner often requires a standing position and hence a new scanning method is needed to improve the accessibility for 3D body scanning. This study aimed to create a scanning scenario and an algorithm for scanning amputation stumps for individualizing prosthesis socks for upper-body amputations. Vitronic VITUSSMART LC 3D Body Scanner was used in this study. The results show a seated position with arms slightly away from the body, scanned at 45° as the best. To measure the right upper arm and the left armpit, the best was to scan at a 315° angle. Paired t-tests showed no significant differences compared with the 3D body scanner of traditional manual measurements. The proposed method exhibited good relative reliability and potential to facilitate the customization of prosthetic socks for amputees.
Subject
General Materials Science
Reference16 articles.
1. Sandsjö, L., Guo, L. (2018). Scan-to-knit—A platform for personalised smart textiles research and development with a special focus on prosthetics. In ISEK 2018—The XXII Congress of the International Society of Electrophysiology and Kinesiology, 222–223.
2. Carroll, K., Edelstein, J. (2006). Prosthetics and patient management: A comprehensive clinical approach (1st ed.). Slack, Thorofare, NJ.
3. Geil, M. D. (2005). Consistency and accuracy of measurement of lower-limb amputee anthropometrics. The Journal of Rehabilitation and Development 42(2), 131–140. doi: 10.1682/JRRD.2004.05.0054.
4. Sims, R. E., Marshall, R., Gyi, D. E., Summerskill, S. J., Case, K. (2012). Collection of anthropometry from older and physically impaired persons: Traditional methods versus TC 2 3D body scanner. International Journal of Industrial Ergonomics, 42(1), 65–72. doi: 10.1016/j.ergon.2011.10.002.
5. SS-EN ISO 7250-1:2017. Basic human body measurements for technological design—Part 1: Body measurement definitions and landmarks.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献