Abstract

Abstract Introduction An airway exchange catheter is a hollow-lumen tube able to deliver oxygen and maintain access to a difficult endotracheal airway. This case report demonstrates an undocumented complication associated with an airway exchange catheter and jet ventilation, particularly in a patient with reduced airway diameter due to thick endotracheal secretions. Due to the frequent use of airway exchange catheters in the intensive care unit, this report highlights an adverse event of bilateral pneumothoraces that can be encountered by clinicians. Case Presentation This case report describes a 24-year-old female with severe adult respiratory distress syndrome and thick endotra-cheal secretions whose hospital course was complicated by bilateral pneumothoraces resulting from the use of an airway exchange catheter connected to jet ventilation. During the exchange, the catheter occluded the narrowed endotracheal tube to create a one-way valve that led to excessive lung inflation. Conclusion Airway exchange catheters used with jet ventilation in a patient with a narrowed endotracheal tube and reduced lung compliance have the potential risk of causing a pneumothorax. Clinicians should avoid temporary concomitant oxygenation via jet ventilation in patients with these findings and reserve the use of airway exchange catheters for difficult airways.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Removal of broken airway exchanger in a patient post thyroid surgery;Trends in Anaesthesia and Critical Care;2024-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3