Estimation of body composition and water data depends on the bioelectrical impedance device

Author:

Bellafronte Natália T.1,Batistuti Marina R.2,dos Santos Nathália Z.1,Holland Héric1,Romão Elen A.1,G. Chiarello Paula1

Affiliation:

1. Department of Internal Medicine, Ribeirão Preto Medical School , University of São Paulo , Ribeirão Preto , Brazil

2. Department of Physics and Chemistry , Faculty of Pharmaceutical Sciences , University of São Paulo , Ribeirão Preto , Brazil

Abstract

Abstract Overweight, obese and chronic kidney disease patients have an altered and negative body composition being its assessment important. Bioelectrical impedance analysis is an easy-to-operate and low-cost method for this purpose. This study aimed to compare and correlate data from single- and multi-frequency bioelectrical impedance spectroscopy applied in subjects with different body sizes, adiposity, and hydration status. It was a cross-sectional study with 386 non-chronic kidney disease volunteers (body mass index from 17 to 40 kg/m2), 30 patients in peritoneal dialysis, and 95 in hemodialysis. Bioelectrical impedance, body composition, and body water data were assessed with single- and multi-frequency bioelectrical impedance spectroscopy. Differences (95% confidence interval) and agreements (Bland-Atman analyze) between devices were evaluated. The intraclass correlation coefficient was used to measure the strength of agreement and Pearson’s correlation to measure the association. Regression analyze was performed to test the association between device difference with body mass index and overhydration. The limits of agreement between devices were very large. Fat mass showed the greatest difference and the lowest intraclass and Pearson’s correlation coefficients. Pearson’s correlation varied from moderate to strong and the intraclass correlation coefficient from weak to substantial. The difference between devices were greater as body mass index increased and was worse in the extremes of water imbalance. In conclusion, data obtained with single- and multi-frequency bioelectrical impedance spectroscopy were highly correlated with poor agreement; the devices cannot be used interchangeably and the agreement between the devices was worse as body mass index and fat mass increased and in the extremes of overhydration.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering,Biophysics

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370