Serologic profiling of D variants in donor routine: unveiling the impact on false-negative results and alloimmunization

Author:

Arnoni Carine P.1,Vendrame Tatiane A.1,Silva Flavia S.1,Silva Nayara M.1,Cortez Afonso1,Latini Flavia1,Castilho Lilian2

Affiliation:

1. Colsan-Associação Beneficente de Coleta de Sangue , São Paulo , SP , Brazil

2. Hemocentro-Unicamp , Campinas , SP , Brazil

Abstract

Abstract The high number of D variants can lead to the unnecessary use of Rh immune globulin, overuse of D− RBC units, and anti-D allommunization. D variant prevalence varies among ethnic groups, and knowledge of the main variants present in a specific population, their behavior in serologic tests, and their impact on clinical practice is crucial to define the best serologic tests for routine use. The present study aimed to explore the serologic profile of D variants and to determine which variants are most associated with false-negative D typing results and alloimmunization. Donor samples were selected in two study periods. During the first period, D typing was performed on a semi-automated instrument in microplates, and weak D tests were conducted in tube or gel tests. In the second period, D typing was carried out using an automated instrument with microplates, and weak D tests were performed in solid phase. Samples from patients typed as D+ with anti-D were also selected. All samples were characterized by molecular testing. A total of 37 RHD variants were identified. Discrepancies and atypical reactivity without anti-D formation were observed in 83.4 percent of the samples, discrepant D typing results between donations were seen in 12.3 percent, and D+ patients with anti-D comprised 4.3 percent. DAR1.2 was the most prevalent variant. Weak D type 38 was responsible for 75 percent of discrepant samples, followed by weak D type 11, predominantly detected by solid phase. Among the D variants related to alloimmunization, DIVa was the most prevalent, which was not recognized by serologic testing; the same was true for DIIIc. The results highlight the importance of selecting tests for donor screening capable of detecting weak D types 38 and 11, especially in populations where these variants are more prevalent. In pre-transfusion testing, it is crucial that D typing reagents demonstrate weak reactivity with DAR variants; having a serologic strategy to recognize DIVa and DIIIc is also valuable.

Publisher

Walter de Gruyter GmbH

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3