Affiliation:
1. Josip Juraj Strossmayer University of Osijek , Department of Physics , Osijek , Croatia
Abstract
Abstract
Since air transport became more accessible, more and more people have been exposed to ionising radiation of cosmic origin. Measuring the neutron dose equivalent is a good approximation of total ambient dose equivalent, as neutrons carry about 50 % of the dose at flight altitudes. The aim of our study was to compare our measurements of the neutron component of secondary cosmic radiation dose, taken with passive dosimeters, with the data obtained from a simulation generated by EPCARD software, which is common in assessing flight crew exposure to ionising radiation. We observed deviations (both above and below) from the expected proportion of the neutron component (between 40 and 80 %), which pointed to certain issues with actual passive dosimeter measurement and the EPCARD simulation. The main limitation of the dosimeter are large uncertainties in high energy neutron response, which may result in underestimation of neutron dose equivalent. The main drawback of the software simulation is monthly averaging of solar potential in calculations, which can neglect sporadic high energy events. Since airlines worldwide almost exclusively use software (due to costs and convenience) to estimate the dose received by their crew, it is advisable to retrospectively recalculate the dose taking into account neutron monitor readings when solar activity changes.
Subject
Public Health, Environmental and Occupational Health,Toxicology
Reference22 articles.
1. Bartlett D. Radiation protection aspects of the cosmic radiation exposure of aircraft crew. Radiat Prot Dosim 2004;109:349-55. doi: 10.1093/rpd/nch311
2. UNSCEAR 2008 Report. Sources and effects of ionizing radiation; United Nations Scientific Committee on the Effects of Atomic radiation. Vol I - Report to the General Assembly with Scientific Annexes A and B [displayed 18 May 2020]. Available https://www.unscear.org/docs/publications/2008/UNSCEAR_2008_Report_Vol.I.pdf
3. Poje M, Vuković B, Radolić V, Miklavčić I, Planinić J. Neutron radiation measurements on several international flights. Health Phys 2015;108:344-50. doi: 10.1097/HP.0000000000000192
4. Vuković B, Radolić V, Lisjak I, Vekić B, Poje M, Planinić J. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport. Appl Radiat Isot 2008;66:247-51. doi: 10.1016/j.apradiso.2007.09.001
5. Poje M, Vuković B, Radolić V, Miklavčić I, Faj D, Varga Pajtler M, Planinić J. Mapping of cosmic radiation dose in Croatia. J Environ Radioact 2012;103:30-3. doi: 10.1016/j. jenvrad.2011.08.016
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献