Experimental central composite design-based dispersive liquid-liquid microextraction for HPLC-DAD determination of diazinon in human urine samples: method development and validation

Author:

Mohammadzaheri Reza12,Dogaheh Mehdi Ansari3,Kazemipour Maryam12,Soltaninejad Kambiz4

Affiliation:

1. Department of Chemistry , Science and Research Branch , Islamic Azad University , Kerman , Iran

2. Department of Chemistry , Kerman Branch , Islamic Azad University , Kerman , Iran

3. Department of Pharmaceutics, Faculty of Pharmacy , Kerman University of Medical Sciences , Kerman , Iran

4. Department of Forensic Toxicology , Legal Medicine Research Center, Legal Medicine Organization , Tehran , Iran

Abstract

Abstract Diazinon poisoning is an important issue in occupational, clinical, and forensic toxicology. While sensitive and specific enough to analyse diazinon in biological samples, current methods are time-consuming and too expensive for routine analysis. The aim of this study was therefore to design and validate a simple dispersive liquid-liquid microextraction (DLLME) for the preparation of urine samples to be analysed for diazinon with high performance liquid chromatography with diode-array detector (HPLC-DAD) to establish diazinon exposure and poisoning. To do that, we first identified critical parameters (type and volume of extraction and disperser solvents, pH, surfactant, and salt concentrations) in preliminary experiments and then used central composite design to determine the best experimental conditions for DLLME-HPLC-DAD. For DLLME they were 800 µL of methanol (disperser solvent) and 310 µL of toluene (extraction solvent) injected to the urine sample rapidly via a syringe. The sample was injected into a HPLC-DAD (C18 column, 250×4.6 mm, 5 μm), and the mobile phase was a mixture of acetonitrile and buffer (63:37 v/v, pH 3.2; flow rate: 1 mL/ min). Standard calibration curves for diazinon were linear with the concentration range of 0.5–4 µg/mL, yielding a regression equation Y=0.254X+0.006 with a correlation coefficient of 0.993. The limit of detection and limit of quantification for diazinon were 0.15 µg/mL and 0.45 µg/mL, respectively. The proposed method was accurate, precise, sensitive, and linear over a wide range of diazinon concentrations in urine samples. This method can be employed for diazinon analysis in routine clinical and forensic toxicology settings.

Publisher

Walter de Gruyter GmbH

Subject

Public Health, Environmental and Occupational Health,Toxicology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3