In vitro evaluation of surface characteristics comparing WaterLase (Biolase®) with tungsten carbide burs for composite removal: a pilot study

Author:

Alkandari Mohammed1,Abela Stefan2,Booth Alessandra3,Bister Dirk34

Affiliation:

1. Faculty of Dentistry, Oral & Craniofacial Sciences, King’s College London, Guy’s and St Thomas’ NHS Foundation Trust , London , UK

2. Department of Oral Health , Norfolk and Norwich University Hospital , Norwich , UK , Private Practice , London and Ely, Cambridgeshire , UK

3. Faculty of Dentistry, Oral & Craniofacial Sciences , King’s College London , UK

4. Guy’s and St Thomas’ NHS Foundation Trust , London , UK

Abstract

Abstract Introduction The present ex-vivo study was designed to evaluate the surface roughness and analyse potential adhesive remnants on the enamel surface after composite removal using either an Er:YSGG WaterLase (WL) (Biolase®, Irvine, CA, USA) or a tungsten carbide (TC) bur (Alston, England, UK). Methods An in vitro study was designed using 21 extracted lower premolars. Pre-coated stainless steel brackets (3M Unitek, Monrovia, CA, USA) were bonded on all of the teeth except one, which served as a control. The teeth were allocated into two groups: Group 1 (n = 5), removal of composite with a TC bur. Group 2 (n = 15), removal of composite using the WL. Scanning electron microscope (SEM) imaging and Energy Dispersive X-ray Spectroscopy (EDS) were used to determine the surface roughness and atomic composition of the surfaces. Results Group 1 had a median damage depth of 17.6 µm with a range between 11.5 µ m and 28.7 µ m. Group 2 had a median damage depth of 166.3 µ m, with a range between 86.6 to 263.1 µ m. The depth differences between the two groups were statistically significant (p < 0.001, Mann–Whitney test). The atomic composition of the WL group was similar to sound enamel. The TC group showed a quantitative increase in carbon and silicone by 38.2% and 11.5%, respectively, a decrease in oxygen by 44.1% and an absence of phosphorous and calcium. Conclusion WL is efficient at removing composite from the enamel surface but could result in increased enamel surface roughness in comparison with conventional TC burs.

Publisher

Walter de Gruyter GmbH

Subject

Orthodontics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3