Quality assurance and dosimetric analysis of intensity modulation radiotherapy using compensators for head and neck cancers

Author:

Tyagi Atul,Nangia Sapna1,Chufal Kundan1,Mishra Maninder1,Ghosh Dhananjay1,Supe Sanjay2,Singh Man3

Affiliation:

1. Department of Oncology, Batra Hospital and Medical Research Center, New Delhi, India

2. Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, Karnataka, India

3. Department of Physics, MMH College, Ghaziabad, Uttar Pradesh, India

Abstract

Quality assurance and dosimetric analysis of intensity modulation radiotherapy using compensators for head and neck cancers In this study we describe our experience in implementing compensator based intensity modulated radiotherapy (cIMRT) for head and neck cancer with regard to pre treatment quality assurance (QA), dosimetric parameters and other technical detail. This study represents the analysis of initial 48 patients who underwent cIMRT for head and neck cancers. All patients were treated with pre treatment QA in terms of point dose with ion chamber and spatial dose comparison with film dosimetry. In our study for all 48 patients, compensators revealed a deviation in central axis dose of 2% ± 1.8% in terms of cumulative calculated versus measured dose. Target coverage for high dose volume (70 Gy) was adequate in terms of volume receiving 93% and 95% of the prescription dose, which was 98.5% and 97.5% respectively. Parotid and other critical organs were spared adequately. Contralateral parotid (CLP) was spared. V30 Gy and V35 Gy was 55.9% and 36.8% for CLP and average dose was 31.7 Gy. Median variation in cumulative measured dose versus cumulative calculated dose was 1.8% (SD + 1.8) and mean variation was 2.5% (95%CI 1.5, 2.6). Range was 0 to 7%. cIMRT is practically feasible. Our QA tests revealed high degree of concordance between cumulative measured doses versus cumulative calculated doses. All dosimetric parameters were within acceptable limits. The manufacturing of compensator is cumbersome but it is a one time job followed by easy treatment delivery and simple QA procedure, high monitor unit (MU) efficiency and less treatment time. cIMRT is easy to implement and now can be applied to larger number of patients with different type of tumor.

Publisher

Walter de Gruyter GmbH

Subject

Radiology Nuclear Medicine and imaging,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3