Air Flow Analysis for Protective Clothing Ventilation Elements with and Without Constant Cross-Section Area Opening

Author:

Janushevskis A.1,Vejanand S. Rajni1,Gulevskis A.2

Affiliation:

1. 1 Institute of Mechanics and Mechanical Engineering Riga Technical University , 6b, Ķipsalas Str., LV-1048 , Latvia

2. 2 Ekasol Ltd . 15, Jauna Str., Ropazi, LV-2135 , Latvia

Abstract

Abstract In this paper a ventilation element is designed with the constant cross-sectional area of 3.14 mm2 with the outer ring, to study the efficiency of ventilation at three different inlet air velocities (2, 5 and 8 m/s). There are five different cases analysed in the study, in which four cases are with different coordinate values of outer ring and core while the fifth case is studied with ventilation element without outer ring. The results of all five cases are analysed and compared to see the efficiency of ventilation element design. These ventilation elements are attached at ventilation hole at the inner part of the protective jacket. The attached ventilation element increases mechanical strength of the clothing by covering ventilation hole and restricting direct access of insects to the body. Moreover, ventilation elements permit smooth flow of air inside jacket. The objective is to determine which element’s geometrical configuration results in the minimum flow energy losses in the cell flow channel from the inlet to the outlet, which are represented by the pressure difference. Flow energy losses increase with increasing pressure difference (ΔP), and the body cooling reduces if the flow is weakened or there is of lost energy. SolidWorks Flow Simulation is used to calculate the pressure, temperature, and heat flux for the simplified elliptical model of the human body with a protective jacket. The obtained results are compared and analysed to study the concept of constant cross-sectional area in the design of ventilation elements with and without outer ring. The pressure and temperature difference for each case are calculated for the comparison and the obtained results show that the element design without outer ring provides better overall results and less flow energy loss in the cell flow channel than that of element design with outer ring.

Publisher

Walter de Gruyter GmbH

Subject

Psychiatry and Mental health,Neuropsychology and Physiological Psychology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3