Validation of transient time method to calibrate oil flow meters in closed conduits using 123I as the radiotracer

Author:

Gonçalves Eduardo R.1,Brandão Luís E. B.2,Braz Delson1

Affiliation:

1. Nuclear Engineering Program , Federal University of Rio de Janeiro (COPPE/UFRJ) , 2030 Horácio Macedo Ave., Building G, Room 206, University City , Rio de Janeiro , RJ 21941-914 , Brazil

2. Nuclear Engineering Institute, National Nuclear Energy Commission , , Rio de Janeiro , RJ 21941-974 , Brazil

Abstract

Abstract To assure the credibility of commodity transfer operations in the oil and gas industry, calibrated flow meters are used to quantify the movement of fluids in the pipelines. The purpose of this paper is to validate the transient time method (TTM) to calibrate oil flow meters installed in restricted areas, using the 123I-labelled oil as a radiotracer. Traditionally, as proposed by the standard ISO 2975-7:1977 [1] for experiments in an aqueous medium, the TTM is employed by positioning two detectors at separate locations. However, in industrial plants, it is not always possible to install detectors at the distances recommended by the ISO 2975-7. The method proposed in this paper uses four scintillator detectors separated one from each other by 0.30 m and three injections containing 5.0 ml of 123I-labelled oil. The experiments were carried out in an oil flow rig with a turbulent flow profile. The results have reached an uncertainty which is lower than 1.0%.

Publisher

Walter de Gruyter GmbH

Subject

Waste Management and Disposal,Condensed Matter Physics,Safety, Risk, Reliability and Quality,Instrumentation,Nuclear Energy and Engineering,Nuclear and High Energy Physics

Reference24 articles.

1. International Organization for Standardization. (1977). Measurement of water flow in closed conduits – Tracer methods – Part 7: Transit time method using radioactive tracers. ISO 2975-7:1977.

2. International Organization for Standardization. (2005). Measurement of fluid flow – Procedures for the evaluation of uncertainties. ISO 5168:2005.

3. British Standard. (1980). Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow. Transit time method using radioactive tracers. BS 5857-1.5:1980.

4. Alberta Energy Regulator. (2018). Measurement requirements for oil and gas operations. Directive 017.

5. Genesis Oil & Gas Consultants Ltd. (2007). Uncertainty assessment of quality measurements in relation to EU ETS requirements – guidance for offshore oil and gas production facilities – proposals for flow meter uncertainty values. Aberdeen. (GENESIS JOB NUMBER: J-70695/A).